Testing Laboratory
(System 3)
EN 1279-5:2005+A2:2010
EN 1279-5:2018
2000/245/EC Flat glass, profiled glass and glass-block products (5/6) -
Flat curved glass panels (specially treated) (for uses
relating energy conservation and/or noise reduction).
Testing Laboratory
(System 3)
EN 15651-1:2012
2011/19/EU Sealants for non-structural use joints buildings and
pedestrian walkways (1/2) Sealants for sanitary joints (for
uses building construction).
Product
Certification Body
(System 1)
EN 15651-1:2012
EN 15651-2:2012
EN 15651-3:2012
EN 15651-4:2012
2011/19/EU Sealants for non-structural use joints buildings and
pedestrian walkways (2/2) Sealants for non-structural use
in joints buildings and pedestrian walkways (for uses
subject reaction fire regulations).
Testing Laboratory
(System 3)
EN 15651-4:2012
2011/19/EU Sealants for non-structural use joints buildings and
pedestrian walkways (1/2) Sealants for glazing (for uses in
building construction).Věstník 4/2021
60
decision product family, product/intended use avcp system technical specification
Flat curved glass panels (for uses subject reaction fire
regulations).
Testing Laboratory
(System 3)
EN 15651-2:2012
2011/19/EU Sealants for non-structural use joints buildings and
pedestrian walkways (2/2) Sealants for non-structural use
in joints buildings and pedestrian walkways (for uses
subject reaction fire regulations).
Testing Laboratory
(System 3)
EN 1279-5:2005+A2:2010
EN 1279-5:2018
2000/245/EC Flat glass, profiled glass and glass-block products (4/6) -
Flat curved glass panels (for other uses liable present
"safety-in-use" risks and subject such regulations).
Product
Certification Body
(System 1)
EAD 030436-00-0503
EAD 030437-00-0503
2011/19/EU Sealants for non-structural use joints buildings and
pedestrian walkways (1/2) Sealants for external walls
(outdoor applications).
FPC Certification
Body (System 2+)
EAD 030352-00-0503
EAD 030436-00-0503
EAD 030437-00-0503
2003/655/EC Watertight coverings kits for wetroom floors and walls (2/2) -
Watertight coverings kits for wetroom floors and walls (for
uses subject regulations reaction fire).
Testing Laboratory
(System 3)
EN 15651-3:2012
2011/19/EU Sealants for non-structural use joints buildings and
pedestrian walkways (1/2) Sealants for pedestrian
walkways (for uses building construction).
Testing Laboratory
(System 3)
EN 1279-5:2005+A2:2010
2003/655/EC Watertight coverings kits for wetroom floors and walls (1/2) -
Watertight covering kits for wetroom floors and walls (for
building works).
Testing Laboratory
(System 3)
EN 15651-1:2012
EN 15651-2:2012
EN 15651-3:2012
EN 15651-4:2012
(*) use facilities outside the testing laboratory the notified body
17 17
.
(System 1279-5:2018
2000/245/EC Flat glass, profiled glass and glass-block products (3/6) -
Flat curved glass panels (for uses subject external fire
performance regulations)