ČAS - Věstník 2021-4

| Kategorie: Firemní tiskovina  | Tento dokument chci!

Vydal: Úřad pro technickou normalizaci, metrologii a státní zkušebnictví

Strana 60 z 87

Jak získat tento dokument?






Poznámky redaktora
Testing Laboratory (System 3) EN 1279-5:2005+A2:2010 EN 1279-5:2018 2000/245/EC Flat glass, profiled glass and glass-block products (5/6) - Flat curved glass panels (specially treated) (for uses relating energy conservation and/or noise reduction). Testing Laboratory (System 3) EN 15651-1:2012 2011/19/EU Sealants for non-structural use joints buildings and pedestrian walkways (1/2) Sealants for sanitary joints (for uses building construction). Product Certification Body (System 1) EN 15651-1:2012 EN 15651-2:2012 EN 15651-3:2012 EN 15651-4:2012 2011/19/EU Sealants for non-structural use joints buildings and pedestrian walkways (2/2) Sealants for non-structural use in joints buildings and pedestrian walkways (for uses subject reaction fire regulations). Testing Laboratory (System 3) EN 15651-4:2012 2011/19/EU Sealants for non-structural use joints buildings and pedestrian walkways (1/2) Sealants for glazing (for uses in building construction).Věstník 4/2021 60 decision product family, product/intended use avcp system technical specification Flat curved glass panels (for uses subject reaction fire regulations). Testing Laboratory (System 3) EN 15651-2:2012 2011/19/EU Sealants for non-structural use joints buildings and pedestrian walkways (2/2) Sealants for non-structural use in joints buildings and pedestrian walkways (for uses subject reaction fire regulations). Testing Laboratory (System 3) EN 1279-5:2005+A2:2010 EN 1279-5:2018 2000/245/EC Flat glass, profiled glass and glass-block products (4/6) - Flat curved glass panels (for other uses liable present "safety-in-use" risks and subject such regulations). Product Certification Body (System 1) EAD 030436-00-0503 EAD 030437-00-0503 2011/19/EU Sealants for non-structural use joints buildings and pedestrian walkways (1/2) Sealants for external walls (outdoor applications). FPC Certification Body (System 2+) EAD 030352-00-0503 EAD 030436-00-0503 EAD 030437-00-0503 2003/655/EC Watertight coverings kits for wetroom floors and walls (2/2) - Watertight coverings kits for wetroom floors and walls (for uses subject regulations reaction fire). Testing Laboratory (System 3) EN 15651-3:2012 2011/19/EU Sealants for non-structural use joints buildings and pedestrian walkways (1/2) Sealants for pedestrian walkways (for uses building construction). Testing Laboratory (System 3) EN 1279-5:2005+A2:2010 2003/655/EC Watertight coverings kits for wetroom floors and walls (1/2) - Watertight covering kits for wetroom floors and walls (for building works). Testing Laboratory (System 3) EN 15651-1:2012 EN 15651-2:2012 EN 15651-3:2012 EN 15651-4:2012 (*) use facilities outside the testing laboratory the notified body 17 17 . (System 1279-5:2018 2000/245/EC Flat glass, profiled glass and glass-block products (3/6) - Flat curved glass panels (for uses subject external fire performance regulations)