BERKER Wiring accessories + Building automation catalogue 2012

| Kategorie: Katalog  | Tento dokument chci!

The use of innovations and new technologies at Hageris always customer-driven. Every year, Hager evaluatesthousands of its customer contacts, resulting in detailedknowledge of its customers’needs in order to workefficiently and successfully.

Vydal: HAGER ELECTRO s.r.o. Autor: EN HAGER

Strana 577 z 616

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.







Poznámky redaktora
7 kA any to DIN 49073 part 1:1990-02 Claw screw fixing EN 61008 part and 2-1: 1994 -25 °C IP20 Plug-in terminals for max.5 mm2 or 1. This applies socket outlets with rated current not greater than A that are intended for use non-experts and for general use. According DIN VDE 0100-410: 2007-06, alternating current systems must be provided with additional protection means residual-current protective devices ≥ mA.5 kA2s 1. The test button "T" can used test the electrical and mechanical functioning. 2.. Optional additional terminal for TN-C systems to VDE 0100 part 540 outgoing terminals 2532 I r=30 mA -25° L PE N Connection diagram TN-S mains 4708. cm plug-in terminals for max. L N Connection diagram TT mains device layout/circuit sketch RCD protection switch Permissible earthing resistance for RCD protection switches for highest permissible electric shock of: - 833 8 - 1666 8 Technical data Rated voltage Rated current RCD-protected outgoing conductor Rated fault current Switch off time Surge energy capacity Rated short circuit capacity Mounting orientation Wall box Attachment Intended use Operating temperature Index protection Outgoing conductors Terminals Insertion depth RCD protection switch order no. Socket outlets connected the residual-current protected outgoing terminals (outgoing feeders) are likewise protected. 2.5 mm2 , approx.5 mm2 32 mm Stranded outgoing conductors are only suitable for screw terminals! outgoing terminals Plug-in terminals outgoing conductors outgoing conductors outgoing conductors Test button Top edge frame Manual operation On Off All other connected sockets are also protected! All other connected sockets are also protected! SCHUKO socket outlet with RCD protection switch RCD protection switch The SCHUKO socket outlet with RCD protection switch and the RCD protection switch must used anywhere that the use residual-current protective devices according VDE 0664 specified. 2844 230 V~, 45-60 Hz 16 A Phase, neutral 30 and pulsating DC 30 ms 250 (8/20) (DIN VDE 0432 part 2) 3 with back-up fuse filament lamp any to DIN 49073 part 1:1990-02 Screw fixing EN 61008 part and 2-1: 1994 -25 °C IP21 stranded 1.5 mm2 or 1. SCHUKO socket outlet with RCD/ Residual Current Device . The integrated switch lever can used switch the SCHUKO socket outlet with RCD protection switch and the RCD protection switch on again after triggering (when testing after eliminating the fault). Exceptions are socket outlets that are constructed exclusively for connecting a specific piece equipment, and socket outlets that are monitored with a residual-current monitor (RCM) qualified electricians persons with electrotechnical training, such one's own commercial industrial systems, for example.5 mm2 32 mm SCHUKO socket with RCD protection switch, increased child-protection and centre plate I r=30 mA -25° SCHUKO socket with RCD protection switch I r=30 mA-25° L PEN Connection diagram TN-C mains Plug-in terminals 4708. Thus all loads connected are equipped with additional protection according DIN VDE 0100 Part 410. Triggering ensured the event fault currents, and pulsating DC fault currents mA.T60 Technical data Rated voltage Rated current RCD-protected outgoing conductor Rated fault current Switch off time Surge energy capacity Rated short circuit capacity Rated switching capacity Im I2t-proof Dynamic current capacity IP Mounting orientation Wall box Attachment Intended use Operating temperature Index protection Terminals Insertion depth Supply package SCHUKO socket with RCD protection switch 230 V~, 45-60 Hz 16 A Phase, neutral 30 and pulsating DC 30 ms 250 (8/20) (DIN VDE 0432 part 2) 3 with back-up fuse filament lamp 500 A 2. The protection goal "Protection against direct contact" according DIN VDE 0100 Part 410 achieved.. L PE N outgoing conductors L PE N Connection diagram TN-S mains L PEN Connection diagram TN-C mains Only plants with existing inventory protection permissible