LEISTUNGSSCHALTER “A” SCHLIESSEN UND KONTROLLIEREN, DASS DER LEISTUNGSSCHALTER “B” NICHT
GESCHLOSSEN WERDEN KANN. REPITA PRUEBA OTRAS TRES VECES LUEGO, COMPRUEBE LOS AJUSTES BLOQUEO LOS TIRANTES.
2. FERMER DISJONCTEUR CONTRÔLER QUE DISJONCTEUR PEUT PAS ÊTRE FERMÉ. TERMINE DEI TEST VERIFICARE REGOLAZIONI BLOCCAGGIO DEI
TIRANTI.: +39 035 395.
2.abb.
CONTROLE MECANIQUE
REARMER LES RESSORTS DES COMMANDES DES DISJONCTEURS EFFECTUER LES OPERATIONS SUIVANTES:
1.
2. CIERRE INTERRUPTOR “A” CONTROLE QUE INTERRUPTOR PUEDA CERRARSE. RÉARMER LES RESSORTS COMMANDE VÉRIFIER QUE DISJONCTEUR RESTE FERMÉ. RESET THE SPRINGS THE CIRCUIT-BREAKER CONTROL AND MAKE SURE THAT THE “B” CIRCUIT-BREAKER
REMAINS CLOSED
5.A. CHIUDERE L'INTERRUTTORE “A” CONTROLLARE CHE L'INTERRUTTORE “B” NON POSSA ESSERE CHIUSO. RÉARMER LES RESSORTS COMMANDE VÉRIFIER QUE DISJONCTEUR RESTE FERMÉ. FEDERN DES ANTRIEBS VON “B” ZURÜCKSTELLEN UND ÜBERPRÜFEN, DASS DER LEISTUNGSSCHALTER “B”
GESCHLOSSEN BLEIBT. REARME LOS MUELLES DEL MANDO “B” COMPRUEBE QUE ESTE INTERRUPTOR PERMANEZCA CERRADO
5.
Via Baioni, 35
24123 Bergamo Italy
Tel.
2. CIERRE INTERRUPTOR “B” CONTROLE QUE INTERRUPTOR “A” PUEDA CERRARSE. REARME LOS MUELLES DEL MANDO “A” COMPRUEBE QUE ESTE INTERRUPTOR PERMANEZCA CERRADO. RESET THE SPRINGS THE “A” CIRCUIT-BREAKER CONTROL AND MAKE SURE THAT THE “A” CIRCUIT-BREAKER
REMAINS CLOSED
3.com
. FIN DES TESTS, VÉRIFIER LES RÉGLAGES BLOCAGE DES TIRANTS
CONTROL MECÁNICO
RESTABLECER LOS RESORTES LOS MANDOS LOS INTERRUPTORES EFECTUAR LAS SIGUIENTES
OPERACIONES:
1.
MECHANICAL CHECK
RESET THE CIRCUIT-BREAKERS OPERATING MECHANISM SPRINGS AND PERFORM THE FOLLOWING OPERATIONS:
1. RÉPÉTER TEST FOIS.
A i
M m
ABB SACE S. RIARMARE MOLLE DEL COMANDO “A” VERIFICARE CHE L'INTERRUTTORE “A” RIMANGA CHIUSO
3. CLOSE THE “B” CIRCUIT-BREAKER AND MAKE SURE THAT THE “A” CIRCUIT-BREAKER CANNOT CLOSED. TEST DREI MAL WIEDERHOLEN. FEDERN DES ANTRIEBS VON “A” ZURÜCKSTELLEN UND ÜBERPRÜFEN, DASS DER LEISTUNGSSCHALTER “A”
GESCHLOSSEN BLEIBT
3. REPEAT THE TEST THREE TIMES, THEN CHECK THE ADJUSTMENTS AND THE FASTNESS THE TIE-RODS.
3.
MECHANISCHE KONTROLLE
DIE FEDERN DER ANTRIEBE DER LEISTUNGSSCHALTER WIEDER SPANNEN UND FOLGENDE SCHALTUNGEN
AUSFÜHREN:
1.
4.
5.ZB
CONTROLLO MECCANICO
RIARMARE MOLLE DEI COMANDI DEGLI INTERRUTTORI ESEGUIRE SEGUENTI OPERAZIONI:
1. CLOSE THE “A” CIRCUIT-BREAKER AND MAKE SURE THAT THE CIRCUIT-BREAKER CANNOT CLOSED. LEISTUNGSSCHALTER “B” SCHLIESSEN UND KONTROLLIEREN, DASS DER LEISTUNGSSCHALTER “A” NICHT
GESCHLOSSEN WERDEN KANN.
4. CHIUDERE L'INTERRUTTORE “B” CONTROLLARE CHE L'INTERRUTTORE “A” NON POSSA ESSERE CHIUSO
4.
5. FERMER DISJONCTEUR CONTRÔLER QUE DISJONCTEUR PEUT PAS ÊTRE FERMÉ. RIARMARE MOLLE DEL COMANDO “B” VERIFICARE CHE L'INTERRUTTORE “B” RIMANGA CHIUSO
5.
3. RIPETERE TEST PER VOLTE.111 Telefax: +39 035 395.
4.p.
4.
2.306-433
http://www