g.
bolts (high strength friction grip bolts), studs, screws, railway
fasteners (for uses structural metallic works).
They can unprotected protected against corrosion by
coating, welded not.
FPC Certification
Body (System 2+)
EAD 200050-00-0102
98/214/EC Structural metallic products and ancillaries (2/4) Weldmesh
gabion boxes and mattresses (for uses work's frames and
foundations).
fire compartmentation)).
FPC Certification
Body (System 2+)
EAD 200002-00-0602
EAD 200039-00-0102
EN 1090-1:2009+A1:2011
98/214/EC Structural metallic products and ancillaries (2/4) Gabion
boxes, mattresses and sack gabions made hexagonal
regular twisted mesh with pre-coated zinc and/or
zinc+organic coating (for uses work's frames and
foundations), Structural metallic construction members:
finished metal framing for suspended ceilings (heavy duty).
Testing Laboratory
(System 3)
EN 14509:2013
11 24
.
FPC Certification
Body (System 2+)
EN 13479:2004
98/214/EC Structural metallic products and ancillaries (4/4) Structural
connectors: metallic rivets, bolts (nuts and washers) and H. The nailed shear connector can either be
used new buildings for the renovation existing
buildings with the aim increase the bearing capacity of
aged floor constructions). They can be
unprotected protected against corrosion coating, welded
or not.R.Věstník 4/2018
57
decision product family, product/intended use avcp system technical specification
subject reaction fire requirements).
FPC Certification
Body (System 2+)
EAD 200019-00-0102
EN 10025-1:2004
EN 10088-4:2009
EN 10088-5:2009
EN 10210-1:2006
EN 10219-1:2006
EN 10340:2007
EN 10340:2007/AC:2008
EN 10343:2009
EN 15048-1:2007
EN 15088:2005
98/214/EC Structural metallic products and ancillaries (1/4) Nailed
shear connector (connexion device between steel and
concrete composite beams and composite decks according
to 1994-1-1.
FPC Certification
Body (System 2+)
EAD 200020-00-0102
98/214/EC Structural metallic products and ancillaries (3/4) Welding
materials (for uses structural metallic works).
FPC Certification
Body (System 2+)
EAD 200026-00-0102
EAD 330080-00-0602
EAD 330153-00-0602
EN 14399-1:2005
EN 14399-1:2015
98/279/EC Non load bearing permanent shutterings: kits/systems based
on hollow blocks panels insulating materials and,
sometimes, concrete (1/1) Non load-bearing permanent
shuttering kits/systems, filled with normal concrete and,
where relevant, with reinforcement, based either: panels
made insulating material (or combination an
insulating material and other materials), consisting of
shuttering leaves linked spacers (for the construction of
external and internal walls not subject fire regulations, in
buildings). (for uses work's frames and foundations).
FPC Certification
Body (System 2+)
ETAG 009 Art 66(3)
98/436/EC Roof coverings, rooflights, roof windows and ancillary
products (1/6) Factory-bonded composite sandwich
panels (for uses subject resistance fire regulations (e. Certification Body
(System 1)
98/214/EC Structural metallic products and ancillaries (1/4) Structural
metallic sections/profiles: hot rolled, cold formed otherwise
produced sections/profiles with various shapes (T, Z,
I, channels, angle, hollow, tubes), flat products (plate, sheet,
strip), bars, castings, forgings made various metallic
materials, unprotected protected against corrosion by
coating (to used metal structures composite metal
and concrete structures). (for uses work's frames).
FPC Certification
Body (System 2+)
EAD 200033-00-0602
98/214/EC Structural metallic products and ancillaries (2/4) Structural
metallic construction members: finished metallic products
such trusses, girders, columns, stairs, ground piles,
bearing piles and sheet piling, cut size sections designed
for certain applications, and rails and sleepers