OMNIMATE – Device connectivity and electronics housings

| Kategorie: Katalog  | Tento dokument chci!

Weidmüller is a leading international provider of solutions for electrical connectivity,transmission and conditioning of power, signal and data in industrial environments.The company with headquarters in Detmold/Germany develops, produces and sellsproducts in the field of electrical connectivity and electronics all over the world.

Vydal: Weidmüller, s.r.o. Autor: Weidmueller

Strana 620 z 707

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.







Poznámky redaktora
3: If the design the field wiring terminals … will preclude the possibility reduced spacing due stray strands improper connections, clearance and creepage distances the field wiring terminal may be evaluated accordance with 840. • For more detailed information, please refer the drawing below. UL840UL508C applications UL1059 components 150 300 600 .2 and 36. Exception: When the design of the field wiring terminals preclu- des the possibility reduced spacing due stray strands or improper wiring installation, then clearance and creepage distances at these ter­minals are able be evaluated accordance with the Standard for Insulation Coordination Including Clearance and Creepage Dis­tan­ces for Electrical Equipment, 840. • The application designer must refer to the application-related standards, not 1059. The clearances shall deter- mined physical measurement. The approval for higher voltages 508C 840: UL 1059 testing conditions: • Measurement clearance and creepage distances directly the product.4 for details applying UL 840. • 508C enables the use field terminals approved 1059 for 300 used for 600  V applications under certain conditions.9 Spacings for drives evaluated accordance with 840) 36.1 Other than noted 36. • Weidmüller Powermate Range plug-in connectors and power terminals comply with the conditions and may be used for 600 applications UL 508C.10 Technicalappendix W UL design-in recommendations for 600 applications Summary the most important UL requirements: • PCB components are approved UL 1059 and are tested without PCB application environment.2.9.W.9. See 36.g. UL [V] Exception, see 508C 36.3. Design-in recommendations: applications for 600 V in accordance with UL Extract from 508C: (36.2 Clearances between uninsu­ lated live part and the walls a metal enclosure, including fittings for conduit armored cable, shall be accordance with 36.9.9.9. 36. • Accepted for applications 508C without further requirements.3 The clearance and creepage distance field wiring terminals shall accordance with the requirements 36.3, clearance and creepage distances are able evaluated in accordance with the require- ments the Standard for Insula­ tion Coordination Including Clear­ ance and Creepage Distances for Electrical Equipment, 840.2. • Applications are approved 508 (or 508C Power Conversion Equipment, e.9.9.1. frequency converters). 36