Poznámky redaktora
Ⴠ Permissible temperature
+600°C +800°C
(up +1200°C for short time)
Ⴠ Braiding special mineral fibres and
additional impregnation with silicone
HELUTHERM® 800-ES
Ⴠ Nominal voltage 500 per above
Ⴠ Test voltage 2000 Additional braided high-grade steel,
coverage approx. km
Nickel
weight
kg km
Max.
Good characteristics the presence moisture and chemical effects. The high-grade braiding also gives
this cable attractive appearance.
mm²
Part no.
current carrying
capacity
at +700°C (A)
Conductor
resistance
at 20°C
Ohm km
Outer Ø
approx. permiss. The braided screen can also used for earthing purposes. 80%
Ⴠ Minimum bending radius
15x outer Ø
Application
HELUTHERM® 800
Cables are used applications where extremely high connecting and ambient temperatures occur, iron and steel works, rolling mills, foundries,
glass and ceramic plants, power construction well for wiring resistances electrical heating equipment, furnaces and thermoplastic forming. mm
Conductor
construction
No.
Weight
approx. (RK01)
314
Single Conductors
Suitable accessories can found Chapter X.
Weight
approx. km
Nickel
weight
kg km
Max.
= The product conformed with the Low-Voltage Directive 2006/95/EC.
20
23,0
4,8
2
175
3,5
7 0,3
1 0,5
50488
18
31,0
7,2
3
115
3,8
11 0,3
1 0,75
50489
17
40,0
9,6
4
88
4,1
14 0,3
1 1
50490
16
47,0
14,4
5
59
4,5
21 0,3
1 1,5
50491
14
59,0
24,0
7
35
4,9
35 0,3
1 2,5
50492
12
82,0
38,0
9
22
5,8
56 0,3
1 4
50493
10
118,0
58,0
12
14,6
7,3
84 0,3
1 6
50494
8
209,0
96,0
14
8,8
9,4
140 0,3
1 10
50495
6
298,0
154,0
20
5,5
10,5
228 0,3
1 16
50496
4
452,0
240,0
24
3,5
12,2
354 0,3
1 25
50497
2
592,0
336,0
40
2,5
15,5
495 0,3
1 35
50498
1
650,0
480,0
48
1,5
16,1
707 0,3
1 50
50499
Dimensions and specifications may changed without prior notice.
HELUTHERM® 800
AWG-No.HELUTHERM® 800 800-EShalogen-free high-grade steel braiding
Properties
Cable structure
HELUTHERM® 800
Technical data
Ⴠ Ⴠ
Special core insulation for high
temperatures
Asbestos and cadmium-free
Ⴠ Stranded nickel conductor
Ⴠ Temperature range
-120°C +750°C
Note
Ⴠ Double-insulated glass-fibre braiding,
impregnated with silicone AWG sizes are approximate equivalent
values.
current carrying
capacity
at +700°C (A)
Conductor
resistance
at 20°C
Ohm km
Outer Ø
approx. mm
Conductor
construction
No.
• Core end sleeve ADI
• Core end sleeve ADU
. The actual cross-section mm².cores x
cross-sec.
24
10,2
2,4
1
346
2,2
4 0,3
1 0,25
51716
20
12,0
4,8
2
175
2,3
7 0,3
1 0,5
51717
18
16,0
7,2
3
115
2,9
11 0,3
1 0,75
51718
17
19,0
9,6
4
88
3,2
14 0,3
1 1
51719
16
26,5
14,4
5
59
3,2
21 0,3
1 1,5
51720
14
38,8
24,0
7
35
3,7
35 0,3
1 2,5
51721
12
57,0
38,0
9
22
4,5
56 0,3
1 4
51722
10
81,0
58,0
12
14,6
5,9
84 0,3
1 6
51723
8
156,0
96,0
14
8,8
8,0
140 0,3
1 10
51724
6
240,0
154,0
20
5,5
9,0
228 0,3
1 16
51725
4
370,0
240,0
24
3,5
10,6
354 0,3
1 25
51726
2
490,0
336,0
40
2,5
13,4
495 0,3
1 35
51727
1
645,0
480,0
48
1,5
14,0
707 0,3
1 50
51728
HELUTHERM® 800-ES
AWG-No.
HELUTHERM® 800-ES
The robust braiding high-grade steel protects the cable from aggressive atmospheres and mechanical stresses. permiss.
mm²
Part no.cores x