Poznámky redaktora
mm
Conductor
construction
No.
mm²
Part no.
Weight
approx. (RK01)
313
Single Conductors
K
Suitable accessories can found Chapter X.
current carrying
capacity
at +400°C (A)
Conductor
resistance
at 20°C
Ohm km
Outer Ø
approx. permiss.
HELUTHERM® 600
AWG-No. permiss. The high-grade braiding also gives
this cable attractive appearance.cores x
cross-sec.
• Core end sleeve ADI
• Core end sleeve ADU
. mm
Conductor
construction
No.
Weight
approx. 80%
Ⴠ Minimum bending radius
15x outer Ø
Application
HELUTHERM® 600
Cables are used applications where extremely high connecting and ambient temperatures occur, iron and steel works, rolling mills, foundries,
glass and ceramic plants, power construction well for wiring resistances electrical heating equipment, furnaces and thermoplastic forming.
= The product conformed with the Low-Voltage Directive 2006/95/EC. km
Nickel
weight
kg km
Max. The actual cross-section mm².
Ⴠ Permissible temperature
+400°C +600°C
(up +700°C for short time)
Ⴠ Braiding special mineral fibres and
additional impregnation with silicone
HELUTHERM® 600-ES
Ⴠ Nominal voltage 500 per above
Ⴠ Test voltage 2500 Additional braided high-grade steel,
coverage approx.
20
21,0
4,8
2,5
175
3,2
7 0,3
1 0,5
50475
18
29,0
7,2
4,5
115
3,5
11 0,3
1 0,75
50476
17
38,0
9,6
5,5
88
3,7
14 0,3
1 1
50477
16
44,0
14,4
7
59
4,1
21 0,3
1 1,5
50478
14
56,0
24,0
10
35
4,6
35 0,3
1 2,5
50479
12
78,0
38,0
13,5
22
5,4
56 0,3
1 4
50480
10
112,0
58,0
16
14,6
6,9
84 0,3
1 6
50481
8
198,0
96,0
21
8,8
8,9
140 0,3
1 10
50482
6
281,0
154,0
28
5,5
10,0
228 0,3
1 16
50483
4
410,0
240,0
36
3,5
11,7
354 0,3
1 25
50484
2
536,0
336,0
58
2,5
15,1
495 0,3
1 35
50485
1
697,0
480,0
70
1,5
15,6
707 0,3
1 50
50486
Dimensions and specifications may changed without prior notice. The braided screen can also used for earthing purposes. km
Nickel
weight
kg km
Max.
Good characteristics the presence moisture and chemical effects.cores x
cross-sec.
24
9,5
2,4
1,5
346
2,0
4 0,3
1 0,25
51703
20
11,5
4,8
2,5
175
2,3
7 0,3
1 0,5
51704
18
15,0
7,2
4,5
115
2,6
11 0,3
1 0,75
51705
17
17,8
9,6
5,5
88
2,8
14 0,3
1 1
51706
16
24,0
14,4
7
59
3,2
21 0,3
1 1,5
51707
14
36,0
24,0
10
35
3,7
35 0,3
1 2,5
51708
12
54,5
38,0
13,5
22
4,5
56 0,3
1 4
51709
10
77,0
58,0
16
14,6
6,0
84 0,3
1 6
51710
8
150,0
96,0
21
8,8
8,0
140 0,3
1 10
51711
6
225,0
154,0
28
5,5
9,1
228 0,3
1 16
51712
4
340,0
240,0
36
3,5
10,8
354 0,3
1 25
51713
2
440,0
336,0
58
2,5
13,0
495 0,3
1 35
51714
1
600,0
480,0
70
1,5
13,5
707 0,3
1 50
51715
HELUTHERM® 600-ES
AWG-No.
HELUTHERM® 600-ES
The robust braiding high-grade steel protects the cable from aggressive atmospheres and mechanical stresses.
mm²
Part no.
current carrying
capacity
at +400°C (A)
Conductor
resistance
at 20°C
Ohm km
Outer Ø
approx.HELUTHERM® 600 600-EShalogen-free high-grade steel braiding
Properties
Cable structure
HELUTHERM® 600
Technical data
Ⴠ Ⴠ
Special core insulation for high
temperatures
Asbestos and cadmium-free
Ⴠ Stranded nickel conductor
Ⴠ Temperature range
-60°C +600°C
Note
Ⴠ Double-insulated glass-fibre braiding,
impregnated with silicone AWG sizes are approximate equivalent
values