HELUKABEL: Katalog kabelů a vodičů 2018 (EN)

| Kategorie: Katalog  |

Vydal: Helukabel CZ s.r.o.

Strana 260 z 1153

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.

Jak získat tento dokument?






Poznámky redaktora
8,7/15kV 3,6/6kV Weight app. weight kg km Tensile strain max. max. Weight app. mm No. mm² Part no. mm No. N Permanent load N Outer Ø min. • Tool HAM.cores x cross-sec. Weight app.cores x cross-sec.5, fine-wire, BS 6360 cl. - 2280,0 1008,0 2200 1500 37,0 40,0 3 10 38533 - 2750,0 1008,0 2200 1500 43,0 46,0 3 10 38545 - 2750,0 1292,0 3100 2000 40,0 43,0 3 10 38534 - 3210,0 1292,0 3100 2000 46,0 48,0 3 10 38546 - 3400,0 1728,0 4300 3000 44,0 47,0 3 10 38535 - 3950,0 1728,0 4300 3000 49,0 52,0 3 10 38547 - 4100,0 2477,0 5100 4100 47,0 50,0 3 16 38536 - 5000,0 2477,0 5100 4100 53,0 57,0 3 16 39040 - 5450,0 3197,0 7000 5600 52,0 56,0 3 16 38537 - 6150,0 3197,0 7000 5600 58,0 62,0 3 16 39041 - 6650,0 4176,0 8500 7100 56,0 60,0 3 120 25 38538 - 7700,0 4176,0 8500 7100 63,0 67,0 3 120 25 39042 6/10kV 12/20kV Weight app.cores x cross-sec. mm No. weight kg km Tensile strain max.(N)TSCGEWÖUextremely torsionally stiff Properties Cable structure Technical data Ⴠ Tinned copper-conductor, to DIN VDE 0295 cl. max.5, IEC 60228 cl. weight kg km Tensile strain max. kg km Cop. weight kg km Tensile strain max. mm² Part no.5 Ⴠ Ⴠ Medium voltage power cable adapted to VDE 0250 part 813 maximum permissible speed 200 m/min is allowed when operating drums one direction Ⴠ Temperature range flexing -20°C +60°C fixed installation -20°C +80°C Ⴠ extremly torsion resistant Ⴠ Inner semi-conducting layer Ⴠ Core insulation HEPR resistant against oils and fats, athmosperic exposure and UV-radiation Ⴠ Nominal voltages U0/U 3,6/6 kV U0/U 6/10 kV U0/U 8,7/15 kV U0/U 12/20 kV Ⴠ Outer semi-conducting layer Note Ⴠ Ground conductor with semi-conductive layer Ⴠ Cores concentrically stranded Ⴠ Inner sheath, sheath colour red Further dimensions and special designs request Ⴠ Antitorsional protection Ⴠ Operating voltages max. max. - 3040,0 1008,0 2200 1500 46,0 49,0 3 10 39043 - 2400,0 1008,0 2200 1500 39,0 42,0 3 10 38539 - 3510,0 1292,0 3100 2000 49,0 52,0 3 10 39044 - 2900,0 1292,0 3100 2000 42,0 45,0 3 10 38540 - 4410,0 1728,0 4300 3000 53,0 57,0 3 10 39045 - 3450,0 1728,0 4300 3000 45,0 48,0 3 10 38541 - 5420,0 2477,0 5100 4100 57,0 61,0 3 16 39046 - 4600,0 2477,0 5100 4100 50,0 54,0 3 16 38542 - 6750,0 3197,0 7000 5600 62,0 66,0 3 16 39047 - 5770,0 3197,0 7000 5600 54,0 58,0 3 16 38543 - 8050,0 4176,0 8500 7100 67,0 70,0 3 120 25 39048 - 6900,0 4176,0 8500 7100 58,0 62,0 3 120 25 38544 Dimensions and specifications may changed without prior notice. kg km Cop.cores x cross-sec. kg km Cop. N Permanent load N Outer Ø min. N Permanent load N Outer Ø min. mm No. mm² Part no. kg km Cop. max. 3,6/6 4,2/7,2 kV 6/10 6,9/12 kV 8,7/15 10,4/18 kV 12/20 13,9/24 kV Ⴠ Outer sheath chloroprene rubber compound type 5GM3 Ⴠ Sheath colour red Ⴠ Test voltages 3,6/6 kV 6/10 kV 8,7/15 kV 12/20 kV Ⴠ Minimum bending radius 15x outer Ø Application Reeling medium voltage supply train for use high mechanical stresses, such container cranes large mobile equipment well excavators in the mining industry for days, dry, damp, wet areas and outdoors. mm² Part no. N Permanent load N Outer Ø min. (RQ03) 258 Trailing Cables Suitable accessories can found Chapter X