Poznámky redaktora
8,7/15kV
3,6/6kV
Weight
app.
weight
kg km
Tensile
strain
max. max.
Weight
app.
mm
No.
mm²
Part no.
mm
No. N
Permanent
load
N
Outer Ø
min.
• Tool HAM.cores x
cross-sec. Weight
app.cores x
cross-sec.5, fine-wire,
BS 6360 cl.
-
2280,0
1008,0
2200
1500
37,0 40,0
3 10
38533 -
2750,0
1008,0
2200
1500
43,0 46,0
3 10
38545
-
2750,0
1292,0
3100
2000
40,0 43,0
3 10
38534 -
3210,0
1292,0
3100
2000
46,0 48,0
3 10
38546
-
3400,0
1728,0
4300
3000
44,0 47,0
3 10
38535 -
3950,0
1728,0
4300
3000
49,0 52,0
3 10
38547
-
4100,0
2477,0
5100
4100
47,0 50,0
3 16
38536 -
5000,0
2477,0
5100
4100
53,0 57,0
3 16
39040
-
5450,0
3197,0
7000
5600
52,0 56,0
3 16
38537 -
6150,0
3197,0
7000
5600
58,0 62,0
3 16
39041
-
6650,0
4176,0
8500
7100
56,0 60,0
3 120 25
38538 -
7700,0
4176,0
8500
7100
63,0 67,0
3 120 25
39042
6/10kV 12/20kV
Weight
app.cores x
cross-sec.
mm
No.
weight
kg km
Tensile
strain
max.(N)TSCGEWÖUextremely torsionally stiff
Properties
Cable structure
Technical data
Ⴠ Tinned copper-conductor, to
DIN VDE 0295 cl. max.5, IEC 60228 cl.
weight
kg km
Tensile
strain
max.
kg km
Cop.
weight
kg km
Tensile
strain
max.
mm²
Part no.5
Ⴠ Ⴠ
Medium voltage power cable adapted to
VDE 0250 part 813
maximum permissible speed 200 m/min is
allowed when operating drums one
direction
Ⴠ Temperature range
flexing -20°C +60°C
fixed installation -20°C +80°C
Ⴠ extremly torsion resistant
Ⴠ Inner semi-conducting layer
Ⴠ Core insulation HEPR resistant against oils and fats, athmosperic
exposure and UV-radiation
Ⴠ Nominal voltages
U0/U 3,6/6 kV
U0/U 6/10 kV
U0/U 8,7/15 kV
U0/U 12/20 kV
Ⴠ Outer semi-conducting layer
Note
Ⴠ Ground conductor with semi-conductive layer
Ⴠ Cores concentrically stranded
Ⴠ Inner sheath, sheath colour red Further dimensions and
special designs request
Ⴠ Antitorsional protection
Ⴠ Operating voltages max. max.
-
3040,0
1008,0
2200
1500
46,0 49,0
3 10
39043
-
2400,0
1008,0
2200
1500
39,0 42,0
3 10
38539
-
3510,0
1292,0
3100
2000
49,0 52,0
3 10
39044
-
2900,0
1292,0
3100
2000
42,0 45,0
3 10
38540
-
4410,0
1728,0
4300
3000
53,0 57,0
3 10
39045
-
3450,0
1728,0
4300
3000
45,0 48,0
3 10
38541
-
5420,0
2477,0
5100
4100
57,0 61,0
3 16
39046
-
4600,0
2477,0
5100
4100
50,0 54,0
3 16
38542
-
6750,0
3197,0
7000
5600
62,0 66,0
3 16
39047
-
5770,0
3197,0
7000
5600
54,0 58,0
3 16
38543
-
8050,0
4176,0
8500
7100
67,0 70,0
3 120 25
39048
-
6900,0
4176,0
8500
7100
58,0 62,0
3 120 25
38544
Dimensions and specifications may changed without prior notice.
kg km
Cop.cores x
cross-sec.
kg km
Cop. N
Permanent
load
N
Outer Ø
min. N
Permanent
load
N
Outer Ø
min.
mm
No.
mm²
Part no.
kg km
Cop. max.
3,6/6 4,2/7,2 kV
6/10 6,9/12 kV
8,7/15 10,4/18 kV
12/20 13,9/24 kV
Ⴠ Outer sheath chloroprene rubber
compound type 5GM3
Ⴠ Sheath colour red
Ⴠ Test voltages
3,6/6 kV
6/10 kV
8,7/15 kV
12/20 kV
Ⴠ Minimum bending radius
15x outer Ø
Application
Reeling medium voltage supply train for use high mechanical stresses, such container cranes large mobile equipment well excavators
in the mining industry for days, dry, damp, wet areas and outdoors.
mm²
Part no. N
Permanent
load
N
Outer Ø
min. (RQ03)
258
Trailing Cables
Suitable accessories can found Chapter X