Poznámky redaktora
5
Ⴠ Ⴠ
Special-crane-drum cable to
DIN VDE 0250 part 814
Designed and developed for horizontal
drum-operation
Ⴠ
Ⴠ Permissible running speed to
max. The cables are suitable for outdoor installation dry, damp and wet places well
in open air.
mm²
Part no.kg km
Cop. 120 m/min
Temperature range
flexing -35°C +70°C
fixed installation -40°C +70°C
Ⴠ Core insulation rubber
compound type GI1 to
DIN VDE 0207 part 20
Ⴠ Polychloroprene-rubber (neoprene)-sheath,
extremely cold resistant
Ⴠ max.NSHTÖU drum cable, VDE approved
Properties
Cable structure
Technical data
Ⴠ Tinned copper-conductor, to
DIN VDE 0295 cl. MOhm Outer sheath neoprene
compound type 5GM2 to
DIN VDE 0207 part 21
Ⴠ case high mechanical stress, especially
of high dynamic tensile stress result high
accelaration, the permissible stress must be
defined each case
Ⴠ Minimum bending radius
7,5 cable Ø
Ⴠ Sheath colour black
Ⴠ Radiation resistance
up 20x106 cJ/kg (up Mrad) Tests
Ⴠ Behaviour fire
to DIN VDE 0482-332-1-2
DIN 60332-2-1, IEC 60332-1 (equivalent
DIN VDE 0472 part 804 test method B)
Ⴠ Oil resistant acc.5, fine-wire,
BS 6360 cl.cores x
cross-sec.
weight
kg km
Outer Ø
app. mm
No.
Weight
app.
= The product conformed with the Low-Voltage Directive 2006/95/EC.kg km
Cop.c.5, IEC 60228 cl. to
DINVDE0473-811-404,DINEN60811-404
Note
Ⴠ with green-yellow conductor
Ⴠ AWG sizes are approximate equivalent
values.cores x
cross-sec. The actual cross-section mm². AWG-No. Please read the installation instructions.
Application
Trailing cables are used for high mechanical stress, especially for applications with frequent winding and unwinding with simultaneous tensile and
torsional stress, for building machinery, conveyors, shifts and cranes. (RG01)
256
Trailing Cables
. Temperature conductor
in operation +60°C
in short-circuit +200°C
Ⴠ Due the neoprene outer sheath,
the cables resistant against ozone
and radiation, oils, acids, fats, gazoline,
solvents and chemicals
Ⴠ Core identification DIN VDE 0293
- cores coloured
- from cores, black with continuous
white numbering
Ⴠ Nominal voltage U0/U 0,6/1 kV
Ⴠ max. permissible operating voltages
in three-phase and one-phase
a. lay-length over the
stranding layers
Ⴠ During the installation and operation the
tensile stress conductor may not increase
15 N/mm²
Ⴠ Textile tape Accelaration not more than 0,4 m/s²
Ⴠ Textile braiding protection against torsion,
embedded inner filling sheath
Ⴠ During operation, 1-2 convolutions should
remain the operating drum
Ⴠ Test voltage 2500 V
Ⴠ Insulation resistance
min. system U0/U 0,7/1,2 kV
in direct current system
U0/U 0,9/1,8 kV
Ⴠ Cores stranded (without elongated central
core) with max.
weight
kg km
Outer Ø
app. They are used robust and all weather resistant cables roughest operations
in mining and flexible handling equipment and railway motors.
mm²
Part no. For applications which beyond standard solutions recommend that you fill out our especially developed questionnaire for reeling
cables.
AWG-No. mm
No.
Weight
app.
16
236,0
47,0
13,6
3 1,5
26001 12
510,0
158,0
18,5
4 4
26019
12
635,0
220,0
21,5
5 4
26030
16
274,0
58,0
14,0
4 1,5
26029
16
316,0
81,0
14,5
5 1,5
26002 10
650,0
241,0
21,0
4 6
26020
16
440,0
115,0
18,8
7 1,5
26003 10
800,0
317,0
23,5
5 6
26031
16
606,0
196,0
21,0
12 1,5
26004 8
1010,0
404,0
26,0
4 10
26021
16
696,0
259,0
24,5
16 1,5
26005 8
1200,0
508,0
28,0
5 10
26022
16
750,0
271,0
25,5
18 1,5
26006 6
1300,0
642,0
29,0
4 16
26023
16
1150,0
390,0
27,5
24 1,5
26007 6
1700,0
768,0
31,5
5 16
26032
16
1325,0
432,0
29,5
30 1,5
26008 4
2000,0
1005,0
35,0
4 25
26024
14
305,0
74,0
15,3
3 2,5
26009 2
2610,0
1344,0
37,5
4 35
26025
14
350,0
98,0
16,5
4 2,5
26010 1
3500,0
2010,0
44,5
4 50
26026
14
465,0
124,0
17,5
5 2,5
26011 2/0
4600,0
2688,0
49,0
4 70
26027
14
576,0
168,0
20,0
7 2,5
26012 3/0
6100,0
3648,0
56,0
4 95
26028
14
850,0
308,0
23,5
12 2,5
26013
14
1181,0
451,0
28,0
18 2,5
26014
14
1550,0
615,0
32,5
24 2,5
26015
14
1810,0
770,0
34,0
30 2,5
26016
14
3110,0
1080,0
42,5
40 2,5
26017
14
3200,0
1200,0
46,5
50 2,5
26018
Dimensions and specifications may changed without prior notice