Test conditions for the temperature and humidity dependent measurements must simulate the worst conditions. Afterwards, the cable must still fulfil the electrical and parameters according the 50173 standard.
norms IEC 60794-1-2F1
Tensile performance
This test checks the behaviour the electrical and parameters function the pulling force the data cable, such that occurring during draw-in. This means that the cable loaded with the maximum allowable pulling force.
norms IEC 60794-1-2-E6
Hammer blow
In order determine the resistance data cable against impacts, wedge allowed fall vertically onto the cable.
norms IEC 60794-1-2-E1B
Repeated bending
The behaviour data cable determined, that cable ample bent forwards and backwards 180 degrees several times.
A-16
. Afterwards, the cable must still fulfil the electrical and parameters according the 50173 standard. This not destructive test.Swiss quality its best
The most important test procedures and their functions
Temperature change and humidity
This test procedure checks the electrical parameters (LF and HF) data cable following temperature humidity changes