BERKER Wiring accessories + Building automation catalogue 2012

| Kategorie: Katalog  | Tento dokument chci!

The use of innovations and new technologies at Hageris always customer-driven. Every year, Hager evaluatesthousands of its customer contacts, resulting in detailedknowledge of its customers’needs in order to workefficiently and successfully.

Vydal: HAGER ELECTRO s.r.o. Autor: EN HAGER

Strana 540 z 616

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.







Poznámky redaktora
Detection field The Berker control has very dense, horseshoe shaped detection angle 220, comprising planes with over 145 sectors and 580 switching segments, well additional crawl-under protection. from °C) and switching segment 1 senses positive jump temperature (e. Off/Test „ with LED detection and mode indicator „ limit cut-out „ intelligent load linking „ for wall and ceiling installation „ cable entry from all sides „ vertical and horizontal tilting 0° 16 m 6° 12 m 2,4m 11m 3m7m 0,4m16m 580 switching segments 20m 16m 220° Berker control . Any heat sources triggering unwanted activation can suppressed by means the adjustable sensitivity and the self-adhesive masking elements.0 approx. The Berker control offers high degree protection against ambient light.5 sec. m 4th plane from approx. the ambient brightness increases, the motion detection only ceases evaluated when the pre-set brightness value has been exceeded for least minutes. 7. Mount the Berker control free vibration, because sensor movements, such those caused mounting tree, may also trigger the switch.T23 Mount laterally across the direction movement If person moves laterally across the Berker control, switching segment senses negative jump tempera- ture (e.g. Mounting instructions Do not mount the Berker control directly above/next a light. This prevents the controller from responding merely short-time periods of sub-minimum brightness (such due cloud). To adapt the detection angle on- site conditions, the sensor head can be inclined and rotated.g. 3. min.4 m - high temperature difference If the sensor head aligned about tilt for example (the upper edge the housing forming continuous line with the bottom edge the sensor), the range will be reduced approx. With the adjustable twilight switch you activate the switching function only from a desired activation brightness, you programme daytime operation. min. 7. Extent the detection field: 16 see diagram The monitoring planes are defined follows: 1st plane from approx. from to 20 °C). The range reduced by: rising ground - inclined sensor head - mounting height less than 2. Operating principle The Berker control responds heat movement, such that triggered people or motor vehicles. When mounting the Berker control make sure the controller lens not pointing towards the sun (sensor may da- maged). until the next movement. This makes possible to operate acoustic signal generators monitor entrance door (bell/gong) and lock it for programmemable immunity time sec. against torches) „ delay time sec. This excludes the possibility tampering, such shining torch the controller to prevent from activating.4 m - low temperature difference The range increased by: falling ground - sensor head pointing upwards - mounting height more than 2. The masking elements supplied can be used eliminate sources interference by limiting the detection angle. To so, cut the masking elements as required the size the individual detection planes the desired angle. horizontal position the detection beams may point directly the sun (see illustration). approx. activates when consumers, such lights, are detected. Then detach the masking elements from the backing sheet and affix them smoothly the sensor window. If person moves directly towards the Berker control the temperature remains virtually constant switching seg- ment There may perhaps detection.5 sec. The digital processing movement signals the integrated processor means interference largely suppressed. The unit remains long movements are detected, otherwise the Berker control switches off the end the pre-set delay time. necessary, limit the detec- tion range the sensor with the masking elements supplied.0 approx. m Crawl-under protection approx. The person must approach the Berker control more closely be 'detected'.0 m 3rd plane from approx. This means effective detection and stable ranging. On/4 hrs. As the ambient brightness slowly decreases, motion detection only evaluated when the brightness level has been below the pre-set activation brightness for least 2 minutes. 3.4 m The ranges relate the recommended mounting height of 2. therefore advisable protect the sensor head against exposure to direct sunlight prior mounting the terminating outlet. The optical alignment the sensor head allows you adapt the unit specific on-site conditions. m.0 m 2nd plane from approx. with immunity time setting „ additional functions, controller operation/4 hrs. -0. adjustable „ short-time service 0. A short-time service 0. The visual indicator signals the response the unit. the light cools may detected change of heat and lead reactivation.4 sensor head aligned horizontally, direction move- ment laterally across the Berker control, sufficient tempe- rature difference between moving body and surroundings on level ground. Rotation +70/-70° Tilt -38° +100° Wall mounted Ceiling mounted optimal 1 3 1 3 not optimal TOP TOP Revers e field m onitoring Revers e field m onitoring links/left rechts/right Plane 1 Plane 2 Plane 3 Plane4-1 Plane4-2 Plane4-2 Plane4-1 Plane 3 Plane 2 Plane 10° 0° 0° 0° 0° 0° 35° 35° 35° 35° 35° 35° 35° 35° 35° 35° 35° 35° 35° 35° 35° 35° 35° 35° 35° 35° 0° 0° 0° 0° 0° 0° 0° 75° 75° 75° 75° 75° 75° 75° 75° 75° 75°75° 75° 75° 75° 75° 75° 75° 75° 75° 75° 0° 0° 0° 0° 0° 0° 0° 110° 110° 110° 110° 110° 110° 110° 110° 110° 110° 110° 110° 110° 110° 110° 110° 110° 110° 110° 110° 827 524 827 524 00 Masking covers for the Berker control® Berker control stands for: „ digital, microprocessor-controlled operation „ digital detection signal evaluation „ digital interference signal suppression „ response sensitivity adjustable „ monitoring planes „ detection angle 220° „ crawl-under protection „ range m „ 145 sectors with over 580 switching segments „ non-weather-dependent range consistency „ activation brightness from Lux daytime operation adjustable „ glare-proof (e.g. can additionally set. Mounting instructions The flexible housing construction of the Berker control makes suitable both for wall and ceiling installation