BERKER Wiring accessories + Building automation catalogue 2012

| Kategorie: Katalog  | Tento dokument chci!

The use of innovations and new technologies at Hageris always customer-driven. Every year, Hager evaluatesthousands of its customer contacts, resulting in detailedknowledge of its customers’needs in order to workefficiently and successfully.

Vydal: HAGER ELECTRO s.r.o. Autor: EN HAGER

Strana 524 z 616







Poznámky redaktora
switch-on and switch-off times) Timer function (countdown function) Random function Astronomic function with individual adjustment facility hour minutes Adjustable twilight sensor Summer/winter time Operation on/off extension unit inputs rocker button with NOCs.. 2., 1736. The time switch easy The time switch easy permits programmed, timed switching loads 1000 way the extension unit inputs, rocker button with NOC (normally open) contacts can used switch off manually..5 mm2 1735.T7 5035 red N2 1 L 2948 ON OFF Insert for timer Order-no. Quick saving the switch-on time for switching times and deleting switch-on time for switching times 4 + sec. 500 ms 2 blocks each for Mo-Fr and Sa-So (ON/OFF) ± seconds per month approx. transformers 85% loading) incl. 500 ms max. Pre-set switch-off times after sunrise are retained. Check suitability equipment prior use, inrush current limiters necessary.. programme memories ± minute per month approx. Features: Operation via 4-button control pad 2 independent programme memories for total switching times (e. Operation with extension unit The timer with display The timer permits programmed, timed switching loads 1000 W/VA. way the extension unit inputs, a rocker button with NOC (normally open) contacts can used switch or off manually. hrs. 1738 . Switch-off times which occur after sunrise are executed soon as sunrise occurs.: 1736. Technical data Nominal voltage Relay output Switching capacity Power consumption Security Radio interference suppression Operating temperature Index protection Terminals Usable mountings Time switch N2 1 L 2948 ON OFF Ground Twilight Neutral- conductor Phase Potential-free NOC Extension unit on/off L N Timer with display Order-no.g.5 mm2 or 1. Changes are saved leaving the sub-menu. min. Manual operation has priority all times. with »AU:_1« Automatic ON with »AU:_0« Automatic OFF + sec. Astronomical function By activating the astro programme the switch-on times that occur within the period of daylight are not executed until sunset.: 1735. is also possible switch the lighting depending brightness using twilight sensor.7 W via circuit breaker to 55015 0 °C IP20 Screw-type terminals for max. 2948 min. (no batteries required) to 55015 5 °C IP20 Technical data Operating voltage Switching time interval Reversing time Switching times Accuracy Power reserve Radio interference suppression Operating temperature Index protection Display switch- ing time 2 OFF Mo-Fr Display switch- ing time 3 OFF Sa-Su Display switch- ing time 4 ON Sa-Su Display switch- ing time 4 OFF Sa-Su hour change (delete »--:--« set or Normal- mode Current minute Current year Current month Current day Current hour Timer . min. using insert order no. minute min. for mechanical push- button (rocker button, 2 NOCs) When connecting energy-saving bulbs and electronic ballasts, consider the high inrush currents. Esc abort editing.: 2948 230 V~, 50/60 conductor required 1 potential-free NOC, not suitable for isolating 230 Incandescent lamps and halogen lamps 1000 (ohmic) Tronic transformers 750 (capacitive) Conv. Time switch Easy Order-no. 2948 min. Manual operation has priority all times. to 55015 0 °C IP20 Technical data Operating voltage Switching time interval Reversing time Switching times Accuracy Power reserve Setting range for twilight sensor (1738 only) Timer function (countdown) Random generator Astro programme Radio interference suppression Operating temperature Index protection N L ~ ~ ~ ~ Executed time Programmed time 20:00 Daylight Darkness 1 6 : 4 5 1 6 : 3 6 1 6 : 2 9 1 6 : 2 4 1 6 : 2 2 1 6 : 5 5 1 6 : 2 2 1 8 : 0 8 1 8 : 2 1 1 8 : 3 5 1 8 : 5 2 1 9 : 0 7 1 9 : 2 2 1 9 : 3 8 1 9 : 5 3 2 0 : 0 8 2 0 : 2 2 2 0 : 3 6 2 0 : 4 9 2 1 : 0 1 2 1 : 1 0 2 1 : 2 0 2 1 : 2 6 2 1 : 3 0 2 1 : 3 3 2 1 : 3 3 2 1 : 3 1 2 1 : 2 6 2 1 : 2 0 2 1 : 1 2 2 1 : 0 3 2 0 : 5 3 2 0 : 4 3 2 0 : 3 1 2 0 : 2 0 2 0 : 1 0 1 9 : 5 9 1 9 : 4 8 1 8 : 3 7 1 8 : 2 3 1 8 : 1 5 1 8 : 0 4 1 7 : 5 3 1 7 : 4 2 1 7 : 3 0 1 7 : 1 9 1 7 : 0 7 1 6 : 5 6 1 6 : 4 5 1 6 : 3 7 1 6 : 2 5 1 6 : 2 9 8 : 1 8 Darkness 8 : 1 5 8 : 1 1 8 : 0 3 7 : 5 5 7 : 4 4 7 : 3 3 7 : 2 1 7 : 1 0 7 : 5 8 7 : 4 7 7 : 3 6 7 : 2 5 7 : 1 7 7 : 0 3 6 : 5 2 6 : 4 1 6 : 3 0 6 : 2 0 6 : 0 9 5 : 5 7 5 : 4 7 5 : 3 7 5 : 2 8 5 : 2 0 5 : 1 4 5 : 0 9 5 : 0 7 5 : 0 7 5 : 1 0 5 : 1 4 5 : 2 0 5 : 3 0 5 : 3 9 6 : 1 8 6 : 3 2 6 : 4 7 7 : 0 2 6 : 1 8 6 : 3 3 6 : 4 8 7 : 0 5 7 : 1 9 7 : 3 2 7 : 4 5 7 : 5 5 8 : 0 4 8 : 1 1 8 : 1 6 8 : 1 8 5 : 5 1 6 : 0 4 Summer time 10 505 45 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00 16:00 17:00 18:00 19:00 20:00 21:00 22:00 23:00 Time 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00 16:00 17:00 18:00 19:00 20:00 21:00 22:00 23:00 Time Summer time Week 10 505 45 Astro curve for timer Extension unit connections e.. After minutes without any push-button activity the time switch reverts to normal mode. 300 Lux 1 minute hrs. 1738. Pre-set switch-on times after sunset are retained. The adjacent drawing shows the astronomic curve from week number week number 40, incorporating hour adjustment for summer time (user must switch between winter and summer time). For intermediate and changeover switch circuits Reset factory default possible Power reserve hours (maintenance-free without batteries) Manual operation possible any time Programmed off time 6:10 Executed off time Subject to time changes Normal- mode Manual operation Normal mode long > s Display switch- ing time 1 ON Mo-Fr Display switch- ing time 3 ON Sa-Su Display switch- ing time 2 ON Mo-Fr Display switch- ing time 1 OFF Mo-Fr Current minute Current year Current month Current day > time setting > s Reset + s) minute Current hour ON OFF Mo-Fr Sa-Su ON OFF Automatic Programming Time switch Easy + sec. minute min. transformer power loss 500 (inductive) Fluorescent lamps uncompensated 500 VA, parallel compensated 400 (inductive) Duo circuit 1000 (inductive) Mixed load; capacitive and inductive loads should not mixed 0. (no batteries required) approx. Twilight function (only with mounting with sensor connection): The twilight function activated approximately minutes before sunset (see astronomic curve). With the timer function the lighting switched for pre-set time between minute and hrs and min. hrs. Quick saving the switch-off time for switching times and deleting switching times 4 The push-button functions and are available the menus: Confirm input.. Changes are saved, the display reverts normal mode. ± minutes adjustable hrs.g. using insert order no. Approximately minutes after the brightness has fallen below the pre-set level, the lighting switched on.. With the astronomical function adjustable hour minutes, the switch-on and switch-off times can adjusted the sunrise and sunset times for the specific location