Usměrňovačové systémy DC-Měniče Střídače UPS systémy ...
Poznámky redaktora
01 kQ
Scope delivery BENNING 101
voltage 0. 044033
BENNING
IT 101
4000 digits (illumination)
0.4 kA
RCD testing
typeAC, A
tripping time, tripping current,
contact voltage
phase sequence
voltage, frequency V-500 Hz
item no.01 -24.1 V-600 AC/DC TRUE RMS
supplementary function leakage current, polarization index (PI),
dielectric absorption rate (DAR), automatic
discharge function, null balance the
measuring leads
measured value memory 500 measuring results
measuring category CAT IV600 V
item no.01 Q
1 GQ
resistance
Multifunctional installation testers for complete testing and
efficient troubleshooting electrical systems
• measurement the protective conductor line and the
equipotential bonding line with testing current 200 mA
• measurement the insulation resistance with testing volt
ages 100 250 500 and 1000 V
• line impedance and loop impedance measurement (optional
without tripping the RCD) with calculation the short-
circuit current (PFC/PSC)
• complete testing RCDs with nominal fault currents of
10/30/100/300/500/1000 mA
• measurement contact voltage (without tripping), tripping
time and tripping current (ramp test) residual current
operated device (RCD)
• phase-sequence testing three-phase mains
• voltage measurement 500 and online voltage moni
toring
indicating range
low-impedance resistance
insulation resistance
.01 2000 Q
insulation resistance 1000 MQ
line impedance (L-N/L)
loop impedance (L-PE)
0.32
B t
Safety Instruments BENNING 101, 110 and 120 B
testing electrical systems compliance with the standards
BENNING 101
In tio and esistance rin evice
BENNING 110
In lla tio este r
O ptional accessories r
BENNING /IT /IT 120 B
40 measurement cable BENNING with practical winder, strap,
for the measurement protective and bonding conductors,
connection: safety test
item no. 044039
BENNING 101
In tio and esista nce rin evice________
• measurement insulating resistance and calculation of
the resulting leakage current
• testing voltages 100 250 500 and 1000 V
• selectable limiting values for ISO measurement, green LED
for “PASS", red LED for testing voltage/external voltage
• resistance measurement with testing current 200 mA
for testing protective conductor connections
• measurement polarization index (PI) and dielectric
absorption rate (DAR)
• switchable probe tip for triggering the measuring process
• internal memory for 100 measuring values per measuring function
• TRUE RMS voltage measurement with low-pass filter
• including case, switchable probe tip, silicone measuring
leads, magnetic hook, alligator clips, rubber protective
frame and batteries
CAT 600 V
TRUE RMS
IT 101 BENNING TA5
BENNING 110, BENNING 120 B
In lla tio esters
For tric syste s
a cco DIN VDE 0100 and IEC 60364
BENNING
IT 110
display graphic display (illuminated)
low-impedance resistance 0. 0441000.01 2000 Q
0.01 2000 Q
short-circuit current 0