BENNING produkty

| Kategorie: Leták / Datasheet  | Tento dokument chci!

Usměrňovačové systémy DC-Měniče Střídače UPS systémy ...

Vydal: BENNING CR, s.r.o. Autor: BENNING

Strana 20 z 247

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.







Poznámky redaktora
01 kQ Scope delivery BENNING 101 voltage 0. 044033 BENNING IT 101 4000 digits (illumination) 0.4 kA RCD testing typeAC, A tripping time, tripping current, contact voltage phase sequence voltage, frequency V-500 Hz item no.01 -24.1 V-600 AC/DC TRUE RMS supplementary function leakage current, polarization index (PI), dielectric absorption rate (DAR), automatic discharge function, null balance the measuring leads measured value memory 500 measuring results measuring category CAT IV600 V item no.01 Q 1 GQ resistance Multifunctional installation testers for complete testing and efficient troubleshooting electrical systems • measurement the protective conductor line and the equipotential bonding line with testing current 200 mA • measurement the insulation resistance with testing volt­ ages 100 250 500 and 1000 V • line impedance and loop impedance measurement (optional without tripping the RCD) with calculation the short- circuit current (PFC/PSC) • complete testing RCDs with nominal fault currents of 10/30/100/300/500/1000 mA • measurement contact voltage (without tripping), tripping time and tripping current (ramp test) residual current operated device (RCD) • phase-sequence testing three-phase mains • voltage measurement 500 and online voltage moni­ toring indicating range low-impedance resistance insulation resistance .01 2000 Q insulation resistance 1000 MQ line impedance (L-N/L) loop impedance (L-PE) 0.32 B t Safety Instruments BENNING 101, 110 and 120 B testing electrical systems compliance with the standards BENNING 101 In tio and esistance rin evice BENNING 110 In lla tio este r O ptional accessories r BENNING /IT /IT 120 B 40 measurement cable BENNING with practical winder, strap, for the measurement protective and bonding conductors, connection: safety test item no. 044039 BENNING 101 In tio and esista nce rin evice________ • measurement insulating resistance and calculation of the resulting leakage current • testing voltages 100 250 500 and 1000 V • selectable limiting values for ISO measurement, green LED for “PASS", red LED for testing voltage/external voltage • resistance measurement with testing current 200 mA for testing protective conductor connections • measurement polarization index (PI) and dielectric absorption rate (DAR) • switchable probe tip for triggering the measuring process • internal memory for 100 measuring values per measuring function • TRUE RMS voltage measurement with low-pass filter • including case, switchable probe tip, silicone measuring leads, magnetic hook, alligator clips, rubber protective frame and batteries CAT 600 V TRUE RMS IT 101 BENNING TA5 BENNING 110, BENNING 120 B In lla tio esters For tric syste s a cco DIN VDE 0100 and IEC 60364 BENNING IT 110 display graphic display (illuminated) low-impedance resistance 0. 0441000.01 2000 Q 0.01 2000 Q short-circuit current 0