ABB Vzduchové jističe EMAX E1-E6 Montážní návody a manuály (03)

| Kategorie: Návody k obsluze Montážní návody  | Tento dokument chci!

Vydal: ABB s.r.o, ELSYNN Autor: ABB ELSYnn

Strana 219 z 660

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.







Poznámky redaktora
g. Enter the unit's "Settings" menu 3. Power the relay from any other source 11. Apart from this, absolutely indispensable for the user modify the password and carefully define each modifiable parameter, before putting the PR123/DC into service. With the circuit-breaker open and/or isolated power the unit from the PR030/B 2.3. With the circuit-breaker open and preferably isolated, install the protection unit the circuit-breaker 2.3.4. 13.4 Initial settings If the PR123/DC supplied ready installed the circuit-breaker, ABB SACE set all the variables referring the circuit-breaker or the specific application correctly (e. Vice versa, the PR123/DC supplied separately, will the user set all the necessary parameters correctly.4.3. Model 7 A pparatus Emax DC S cale D oc-N 1SDH000635R0002 Page No. Enter the unit's "Settings" menu 5.. Note that ABB SACE defines each possible setting according the content the paragraph the default parameters (see par. Power the unit ONLY from the PR030/B 3. Check for the absence configuration errors.6. Disabling the Password. therefore always possible to switch from "READ" "EDIT". Remove the PR123/DC unit from the circuit-breaker 9. The values attributable the password from 0000 9999. Select "Circuit-breaker" 4. 13. Select "Circuit-breaker" 6.6 Replacing electronic release 13.13. After entering the fourth figure, check the password you have entered. When the PR120/V module installed, user must properly set the rated voltage.2 Uninstalling To complete the procedure for uninstalling PR123/DC unit, follow the steps below: 1. 13. To enter new password, select the "New Password" item the "Settings/System" menu. Remove the PR030/B 8. Select "Unit installation" 5.5 Password management Specify password? [0***] To enter "EDIT" mode necessary enter four-figure numerical password. Select "Uninstall" and press "ENTER" 7. Select "Install" and press "ENTER" 9. 61/108 .1 Installation To complete the procedure for installing PR123/DC unit, follow the steps below: 1. Input the password 8. 13.. Select "Unit installation" 7. When the red led flashes and off and the message Installation (installation error) displayed, remove the PR030/B 10. The remove the connector, proceed indicated the figure alongside. 13. type circuit-breaker, Rating Plug size. Select the value the first figure between '0' and '9' means the and keys and press confirm the figure and then move enter the next one. there are other errors, the display will show the message Configuration (configuration error) accompanied the yellow LED coming permanently (warning) 4. It not strictly necessary complete the uninstalling procedure, but this enables the parameters relating the circuit-breaker, such contact wear and others, saved, otherwise these data would lost.3. By setting the value the password [0000] (on the "Unit configuration" menu) the password prom disabled. Input the password 6.4. It also possible interrupt the password entry procedure pressing the ESC key.3. the password correct, you from the "READ" state to the "EDIT" state. For the default password see par. The data question are then transmitted the new PR123/DC unit installed on the same circuit-breaker.6.). If the password wrong, the message Wrong password appears and remains until the ESC key pressed (or until interval seconds has elapsed).4)