ABB Softstartéry - opravy, náhradní díly (EN)

| Kategorie: Leták / Datasheet  | Tento dokument chci!

Vydal: ABB s.r.o, ELSYNN Autor: ABB ELSYnn

Strana 59 z 79







Poznámky redaktora
Remove the old HV-Board. Before disconnecting the cables mark them. Remove the front cover (four screws). 10. 2. Disconnect the cables the LV-Board from the thermal switch and current transformers. 5. Mark the cables from the thyristors with L1, and L3. Remove the six screws. Disconnect the cables the HV-Board from the thyristors and fans. Mark the cables from the current transformers with CT1, CT2 and CT3. Disconnect the cables from terminals 1L1, 3L2, and 5L3 (main voltage). -. 8. Discharge the tools and yourselfby touching earth (if you are not earthed). Disconnect all cables from the terminals 1to 20, external keypad, PTC sensor and the Fieldbus plug. 4. 3. 7.Step step 1. 6. Don’t lose the connector between HV-Board and LV- Board. Remove the five screws. 9