7. Remove the front cover (four screws). 8. Don’t lose the connector between HV-Board and LV- Board. Mark the cables from the thyristors with L1, and L3. 3. -. 6. 9. 10. 4. Disconnect all cables from the terminals 1to 20, external keypad, PTC sensor and the Fieldbus plug. Disconnect the cables from terminals 1L1, 3L2, and 5L3 (main voltage). 2. Before disconnecting the cables mark them. Remove the five screws. Disconnect the cables the LV-Board from the thermal switch and current transformers.Step step 1. Disconnect the cables the HV-Board from the thyristors and fans. Remove the old HV-Board. Remove the six screws. 5. Mark the cables from the current transformers with CT1, CT2 and CT3. Discharge the tools and yourselfby touching earth (if you are not earthed)