Poznámky redaktora
.
♦Remove the front cover...
♦Discharge the tools and yourselfby touching earth.
Ready for start!!
Picture Picture Picture Picture 4
Semikron
Thyristor
IXYS
Mounting
torque
Terminal
connection
torque
Picture
SKKT27.SKKT92 MCC26..SKKT330 MCC225.
♦Mount the electrical connection the thyristors.
♦Disconnect the voltage from terminals 1L1, 3L2, and 5L3 (main supply).
Too much compound between module and heat sink will give bad thermal
conduction and cause risk overheating the thyristors...
Use lint-free cloth (paper linen cloth)
♦A very thin layer ofheat transfer compound shall put the contact surfaces of
the modules with lint-free cloth..
♦Connect the voltage and the other cable.
♦Disconnect the thyristors.
♦Mount the new thyristors (Use the torque the table)..SKKT172 MCC132..MCC95 3,0 3,0 1
SKKT132.
♦Disconnect all cable from the terminals.Step step..
♦Mount the front cover.MCC162 3,0 5,0 2
SKKT210.MCC312 3,0 9,0 3
SKKT500 MCC500 3,0Nm 12,0 4
-.
♦Clean the contact surface the heat sink and modules with Ethanol..
♦Disconnect the electrical connection the thyristors.