Retrofitting kits Ordering codes Air circuit-breakers kit Old lcu circuit-breaker [A] [kA] New circuit-breaker Retrofitting kit code Otomax EMAX 3 poles poles Verslor P1 800 800 E1B 800 1SD050748R1 P1 1250 1250 1250 1SD050750R1 P1 1600 1600 E2B 1600 1SD050751R1 P1 2000 2000 E3S 2000 1SD050753R1 P1B 1000 1000 E1B 1250 1SD050748R1 P1B 1600 1600 E2B 1600 1SD050750R1 P1B 2000 2000 E2B 2000 1SD050751R1 P1B 2500 2500 E3N 2500 1SD050753R1 P1C 1000 1000 E1B 1250 1SD050748R1 P1C 1250 1250 E1B 1250 1SD050748R1 P1C 1600 1600 E2B 1600 1SD050750R1 P1C 2000 2000 E2B 2000 1SD050751R1 P1C 2500 2500 E3N 2500 1SD050753R1 P2 800 800 1250 1SD050749R1 P2 1250 1250 1250 1SD050750R1 P2 1600 1600 1600 1SD050751R1 P2 2000 2000 E3S 2000 1SD050753R1 P2 3000 3000 E3N 3200 1SD050754R1 P2 4000 4000 E4S 4000 1SD050756R1 P2B 1000 1000 E2N 1250 1SD050749R1 P2B 1600 1600 1600 1SD050750R1 P2B 2000 2000 E2N 2000 1SD050751R1 P2B 2500 2500 E3N 2500 1SD050753R1 P2B 3000 3000 E3N 3200 1SD050754R1 P2B 4000 4000 E4S 4000 1SD050756R1 P2C 1000 1000 E2N 1250 1SD050749R1 P 1250 1250 1250 1SD050749R1 P2C 1600 1600 1600 1SD050750R1 P2C 2000 2000 E2N 2000 1SD050751R1 P2C 2500 2500 E3N 2500 1SD050753R1 P2C 3200 3200 E3N 3200 1SD050754R1 P2C 4000 4000 E4S 4000 1SD050756R1 P3 1600 1600 E3S 1600 1SD050752R1 P3 2000 2000 E3S 2000 1SD050753R1 P3 3000 3000 100 E4H 3200 1SD050755R1 P3 4000 4000 100 4000 1SD050756R1 P3B 2000 2000 E3S 2000 1SD050752R1 P3B 2500 2500 E3S 2500 1SD050753R1 P3B 3000 3000 100 E4H 3200 1SD050755R1 P3B 4000 4000 100 E4H 4000 1SD050756R1 NOTE Kit available only complete with the new circuit-breaker. Air circuit-breaker retrofitting kit has been studied for Otomax and Novomax G30 circuit-breaker draw out version with rear horizontal terminals. MAIN ACTIVITIES REQUIRED : • Put out service the panel the entire switchboarc • Carry out the moving part the Otomax Novomax circuit-breaker • Remove the fixed part the Otomax Novomax circuit-breaker • workbench fit the branch connections the fixed part the Emax circuit-breaker • Assembly the Emax fixed part with retrofitting kit the switchboard compartment • Drillng templates the compartment door P3C 2000 2000 E3S 2000 1SD050752R1 P3C 2500 2500 E3S 2500 1SD050753R1 P3C 3200 3200 100 E4H 3200 1SD050755R1 P3C 4000 4000 100 4000 1SD050756R1 ALL THE RETROFITTING KITS HAVE BEEN STUDIED FOR REPLACEMENT OLD CIRCUIT- BREAKERS INSTALLED PER INDICATED THE INSTRUCTION MANUALS. 18 ABB SACE . Contact the installed circuit-breakers are different version