WEIDMUELLER Hlavní katalog řadových svorek (EN)

| Kategorie: Katalog  | Tento dokument chci!

Všechny kapitoly z nejnovějšího katalogu řadových svorek a SAK Weidmüller ...

Autor: Weidmüller

Strana 233 z 571

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.







Poznámky redaktora
Type Qty.000 AWG 6. connection for extra conductor “WZAD 240“, Order no.95 50. Type Qty.25 6...240 70. WQV 95/120/2 269 1826890000 WQV 95/120/3 269 1826900000 WQV 95/120/4 269 1826910000 Width WEW 35/1 1059000000 WAD WSD 9512260000 WZAD 95N/120N 12..150 16.16 10..70 6........ Type Qty.35 Copper strips can used..35 16.95 12. Type current Qty.25 Copper straps can used; see online catalogue for possible connections...35 10..131282250000 2012/2013 Compact design WDU 70N mm² 20. 10.. WDU 240 1802780000 WDU 240 1822210000 Aux...240 70.500 240 8 3 B15 V-0 r KEMA 01ATEX2186 U Rated connection Further connection 70. 180281000 (up to 10 mm², ELPF insertion profile, for ribbon cable, Order no..150 IEC CSA 60079-7 1000 1000 (C) 1000 (C) 880 269 228 (C) 220 (C) 243 120 AWG 4..... 1824680000.. Auxiliary connection for additional conductor “WZAD 70N” 1964830000 (up to mm², A). Order No..16 16.5 1859580000 DEK 5/5 12/6,5 IEC 60947-7-1 D WDU 240 240 mm² 36 100 124 415 240 70.16 10.95 35.95 IEC CSA 60079-7 1000 600 (C) 600 (C) 690 192 195 (C) 205 (C) 167 70 AWG 6. See online cat...240 70...240 IEC CSA 60079-7 1000 600 (C) 600 (C) 1100 415 380 (C) 400 (C) 300 240 AWG 0.....250 AWG 4.. Order No.70 10..50 Copper straps can used; see online catalogue for possible connections.... WDU 70N/35 9512190000 WDU 70N/35 9512420000 1000 V and CSA for usage groups and can used with isolating DIN rails and when using WTW-type partitions...D D.... Order No...20 10 27 (DIN 6911) 16.120 16. Order No.5 1964830000 DEK 5/5 12/6,5 IEC 60947-7-1 D Compact design WDU 95N/120N 120 mm² 27 91 290 150 16...... When connecting AWG conductor of 250 kcmil, use stripping length and tightening torque Nm. Order No...5 86 232 95 10..30 10 40 (DIN 6911) / 35. WDU 95N/120N 1820550000 WDU 95N/120N 1820560000 1000 V and CSA for usage groups and can used with isolating DIN rails and when using WTW-type partitions.... Auxiliary connection for additional conductor “WZAD 95N/120N” 1859580000 (up mm², A).. Type current Qty. Order No. WQB 240/2 320 1802790000 WQB 240/3 320 1802800000 Width WEW 35/1 1059000000 WZAD 240 10.0000 120 8 3 B13 V-0 r KEMA 98ATEX1683 U Rated connection Further connection 16...16 10. WQV 70N/2 192 9512240000 WQV 70N/3 192 9512250000 WQV 70N/4 192 9531290000 Width WEW 35/1 1059000000 WAD WSD 9512260000 WZAD 70N 12.....185 25.12 8) 22 (DIN 6911) 10.95 10. Type current Qty..000 70 8 3 B11 V-0 r KEMA 98ATEX1683 U Rated connection Further connection 10.15 1802810000 DEK 5/5 12/6,5 IEC 60947-7-1 D Terminals,W-Series Feed-through terminals ....