Terminal blocks Klippon Connect 2025

| Kategorie: Katalog  | Tento dokument chci!

Vydal: Weidmüller, s.r.o.

Strana 791 z 872







Poznámky redaktora
The minimum air clearance measurement defined IEC 60947-7-1 in conjunction with the rated surge voltage. These rated currents cause no impermissible heat transfer the terminal: mm2 1.2 0.1 lEC 60947-1.0 – 16 120 150 240 300 mm2 . The conductors can solid, stranded or flexible, possibly with conductor end pretreatment. The verification the rated cross-section performed with gauges according IEC 60947-1. Pollution severity has been specified for terminal blocks for industrial applications: conductive contamination occurs dry, non-conductive contamination which becomes conductive as moisture condensation may also occur. Operating conditions The terminal blocks can operated under the following normal conditions: • Ambient temperature +40 °C, mean value +35 °C • Altitude 2000 above sea level • Relative humidity: +40 °C, +20 °C C.75 1. This serves reference for certain thermal, mechanical and electrical requirements. Terminal blocks have rated connection capacity that least two levels lower than the rated cross- section. The rated cross- section selected from the following standard cross- sections: 0. determined analogously IEC 60664-1.2.5 4.5 41 mm2 10 35 A 101 125 mm2 50 120 A 150 192 232 269 mm2 150 185 240 300 A 309 353 415 520 Conventional free-air thermal current (Ith) The conventional thermal current free air (Ith) the highest test current for heating tests unenclosed devices (see 4. Rated impulse withstand voltage IEC 60947-7-1 Rated impulse withstand voltage the peak value surge voltage with which the terminal blocks can subjected.0 1.Technical requirements from the standards Rated cross-section The rated cross-section terminal block the value of the connectable wire cross-section, specified the manufacturer.5 0.0 6. The clearance distances IEC 60947-1 and IEC 60664-1 are related it.0 6.) This applies exclusively to terminal blocks with multiple connection levels (multi-tier terminals) and test-disconnect terminal blocks for which current reduction permissible.5 2.0 A 17.5 2. Rated current IEC 60947-7-1 Test currents are assigned the rated cross-sections according IEC 60947-7-1. Pollution severity IEC 60947-7-1 The pollution severity defines the influence solid, liquid or gaseous foreign matter, which may reduce the dielectric strength the specific surface resistance. Rated voltage IEC 60947-7-1 The rated voltage terminal block the rated insulation voltage which the insulation tests and creepage distances relate.5 4.3.35 CAT1 Version 2025 Installation C Standards and industries