Panasonic is part of a large worldwide groupselling relays and associated switching products under different brand names in different territories.The conditions of use in some territories may differ from those customary in Europe. In particular there are often major differences in regard to national and international specifications, such as UL, CSA, VDE, SEV, EVE, SEMKO, etc. Thus, when considering contact loads as stated in this catalogue (e.g. 10 A, 30 VDC for the SP relay) its hould be understood that these values are not necessarily an absolute maximum but tested ratings. Mostly the stated value has been tested for a certain life expectancy as stated by the manufacturer or the respective test house. Thus, under different conditions, the stated “maximum” may, in practice, be safely exceeded.
Use within the range
indicated the graph below.)
(3) Atmospheric pressure: 106 kPa
The humidity range varies with the
temperature.
(Temperature and humidity range for
usage, transport, and storage)
i Humidity, %RH
-40 85
-40 +32 +185
Temperature, °F
i Humidity, %RH
'(Avoid freezing
✓when used -
'temperatures
Slower than
'0°C 32°F) 5
T 2^
(Avoid
condensation
when used at
temperatures
higher than
0°C 32°F)
-40 85
-40 +32 +185
Temperature, °F
PRECAUTIONS REGARDING LATCHING RELAYS
• Latching relays are shipped from the
factory the reset state. shock the
relay during shipping installation may
cause change the set state. If
connected incorrectly, may malfunction
or fail operate.
• order set reset latch relay, a
guide, apply the square wave rated
voltage for set time five times more
of the reset time for each product and
then verify operation again.
• The positive “+” and negative ”
connections the coil should done as
indicated the wiring diagram.(ACTC)
NOTES
Usage, transport and storage
conditions
1) Ambient temperature, humidity, and
atmospheric pressure during usage,
transport, and storage the relay:
(1) Temperature: +85°C to
+185°F (Standard type)
-4 +110°C -40 +230°F (High heat-
resistant type/Pin Paste type)
(2) Humidity: 85% (Avoid
freezing and condensation.
Therefore, recommended that the
relay used circuit which initializes
the relay the required state (reset)
whenever the power turned on.
For Cautions for Use, see Relay Technical Information (page 166).
92 61282 tc: 310113D
.
• Avoid impressing voltages the set coil
and reset coil the same time