Panasonic is part of a large worldwide groupselling relays and associated switching products under different brand names in different territories.The conditions of use in some territories may differ from those customary in Europe. In particular there are often major differences in regard to national and international specifications, such as UL, CSA, VDE, SEV, EVE, SEMKO, etc. Thus, when considering contact loads as stated in this catalogue (e.g. 10 A, 30 VDC for the SP relay) its hould be understood that these values are not necessarily an absolute maximum but tested ratings. Mostly the stated value has been tested for a certain life expectancy as stated by the manufacturer or the respective test house. Thus, under different conditions, the stated “maximum” may, in practice, be safely exceeded.
Use within the range
indicated the graph below.
(Temperature and humidity range for
usage, transport, and storage)
i Humidity, %RH
0 85
+32 +185
Temperature, °F
A Humidity, %RH
0 85
+32 +185
Temperature, °F
110
230
For Cautions for Use, see Relay Technical Information (page 166).)
(3) Atmospheric pressure: 106 kPa
The humidity range varies with the
temperature.(ACTB)
NOTES
Usage, transport and storage
conditions
1) Ambient temperature, humidity, and
atmospheric pressure during usage,
transport, and storage the relay:
(1) Temperature: -40 +85°C to
+185°F (Standard type)
-4 +110°C +230°F (High heat-
resistant type/Pin Paste type)
(2) Humidity: 85% (Avoid
freezing and condensation.
ds 61280 tb: 010113J 85
Automotive