Panasonic is part of a large worldwide groupselling relays and associated switching products under different brand names in different territories.The conditions of use in some territories may differ from those customary in Europe. In particular there are often major differences in regard to national and international specifications, such as UL, CSA, VDE, SEV, EVE, SEMKO, etc. Thus, when considering contact loads as stated in this catalogue (e.g. 10 A, 30 VDC for the SP relay) its hould be understood that these values are not necessarily an absolute maximum but tested ratings. Mostly the stated value has been tested for a certain life expectancy as stated by the manufacturer or the respective test house. Thus, under different conditions, the stated “maximum” may, in practice, be safely exceeded.
RELAYS
<POWER TYPE>
Panasonic
ideas for life
HIGH CARRYING
CURRENT TYPE
SMALL SLIM
AUTOMOTIVE RELAY
0
FEATURES
• Maximum carrying current 35A
made possible through using the
same size the company's CT
relays
• Plastic sealed type
TYPICAL APPLICATIONS
• Power windows
• Auto door lock
• Power sunroof
• Powered seats
• Slide door closers, etc. 7.
1FormC ACTP112
1FormCx2(8terminalstype) 12VDC ACTP212
1FormCx2(10terminalstype) ACTP512
Standardpacking; 1FormC: Carton(tube) 30pcs.
464 ds_61205_en_ct_power: 010113J
. Case1,500pcs.0VDC(Initial) 83. 1.
RATING
1. Pleasecontact usfordetails. (for motor
forward/reverse control circuits)
ORDERING INFORMATION
ACT P
P:Powertype
Contactarrangement
1FormC
1FormCx2(8terminal)
1FormCx2(10terminal)
Coilvoltage,DC
12:12V
TYPES
Contact arrangement Coil voltage Part No. Coil data
Nominal coil
voltage
Pick-upvoltage
(at20oC68°F)
Drop-outvoltage
(at20oC680F)
Nominal operating
current
[+10%] (at20oC68oF)
Coil resistance
[+10%] (at20oC68oF)
Nominal operating
power
(at20oC68oF)
Usablevoltagerange
12VDC Max.; 1FormCx2: Carton(tube) 30pcs.3mA 144Q 1,000mW 10to16VDC
Note: Otherpick-upvoltagetypesarealsoavailable.2VDC(Initial) Min. Case900pcs