Kategorie: Katalog |
Tento dokument chci!
Panasonic is part of a large worldwide groupselling relays and associated switching products under different brand names in different territories.The conditions of use in some territories may differ from those customary in Europe. In particular there are often major differences in regard to national and international specifications, such as UL, CSA, VDE, SEV, EVE, SEMKO, etc. Thus, when considering contact loads as stated in this catalogue (e.g. 10 A, 30 VDC for the SP relay) its hould be understood that these values are not necessarily an absolute maximum but tested ratings. Mostly the stated value has been tested for a certain life expectancy as stated by the manufacturer or the respective test house. Thus, under different conditions, the stated “maximum” may, in practice, be safely exceeded.
Strana 517 z 1090
«
Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.
»
Jak získat tento dokument?
Poznámky redaktora
*2. appliedvoltage
1FormA
5VDC
75%Vorlessof
nominal voltage
(Initial)
5%Vormoreof
nominalvoltage
(Initial)
40.5Q
12VDC 33.
Notes:
*1.8CFwith20°C68°Fasareference) anduseacoil impressedvoltagethat iswithinthemaximumappliedvoltagerange. switchingcapacity(referencevalue)*1 100mA, 5VDC
Electrical
characteristics
Insulationresistance(Initial) Min. Specifications
Characteristics Item Specifications
Contact
Arrangement 1FormA 1FormC
Contact resistance(Initial) Max. Referto“6. (at nominal switchingcapacity)
Unitweight Approx.)
Vibrationresistance
Functional 10to55Hzat doubleamplitudeof 1. switchingvoltage 250VAC
Max.4mA 202.3mA 360 Q
18VDC 22.)
Destructive 980m/s2(Half-wavepulseofsinewave: 6ms.)
Destructive 10to55Hzat doubleamplitudeof2. operatingspeed 20times/min.
*4.Theupperlimitoftheambienttemperatureisthemaximumtemperaturethat cansatisfythecoil temperaturerisevalue. 1,000MQ(at500VDC) Measurement atsamelocationas“Breakdownvoltage”section.7mA 720 Q
18VDC 11.
ds_61B20_en_lq: 121212D 315
Power
. side: 150W, 1,250VA
N.2mA 405 Q
12VDC 16.Waveisstandardshockvoltageof±1.O.O. switchingpower(resistiveload) 150W, 1,250VA N.H.)
Conditions
Conditionsforoperation, transport andstorage*3 Ambient temperature: -40°Cto+85°C 40°Fto+185°F
Humidity: 5to85%R.
(Detectioncurrent: 10mA)
750Vrmsfor 1min. 100mQ(Byvoltagedrop6VDC1A)
Contact material AgNi type
Rating
Nominal switchingcapacity(resistiveload) 5A30VDC, 10A125VAC, 5A250VAC
N.
(Detectioncurrent: 10mA)
Betweencontact andcoil 4,000Vrmsfor 1min.7mA 1,440 Q
2. switchingcurrent N.1mA 1,620 Q
24VDC 8.C.0mA 125 Q
200mW
180%ofnominalvoltage
(at20°C68°F)
130%ofnominalvoltage
(at 85°C185°F)*4
6VDC 33.3mA 180 Q
9VDC 22.LQ
RATING
1.Whenusingrelaysinahighambienttemperature, considerthepick-upvoltageriseduetothehightemperature
(ariseofapprox.) (Initial)
Releasetime(at nominalvoltage) (at20°C68°F) Max.Thisvaluecanchangeduetotheswitchingfrequency,environmentalconditions,anddesiredreliabilitylevel,thereforeitisrecommendedtocheckthiswiththeactualload. 0.4%Vforeach 1°C33.0mA 62. 107(at 180times/min.C. side: 30W, 500VA
Max. Coil data
Contact
arrangement
Nominalcoil
voltage
Pick-upvoltage
(at20°C68°F)
Drop-outvoltage
(at20°C68°F)
Nominal operating
current
[±10%] (at20°C68°F)
Coil resistance
[±10%] (at20°C68°F)
Nominaloperating
power
(at20oC680F)
Max.6mm(Detectiontime: 10|as.5Q
400mW
150%ofnominalvoltage
(at20°C68°F)
110%ofnominalvoltage
(at85°C185°F)*4
6VDC 66. 45°C113°F(Byresistivemethod, nominal coil voltageappliedtothecoil; contact carrying
current: 10A, at85°C185°F)
Surgebreakdownvoltage*2
(Betweencontact andcoil) 8,000V(Initial)
Operatetime(at nominal voltage) (at20°C68°F) Max.C.: 10A(125VAC), N. 7g.3mA 2,880 Q
1FormC
5VDC
75%Vorlessof
nominal voltage
(Initial)
5%Vormoreof
nominalvoltage
(Initial)
80. side:
10A125VAC, 5A250VAC, 5A30VDC
N. (Detectioncurrent: 10mA)
Temperaturerise(coil)*4 Max.2x50p,saccordingtoJEC-212-1981
*3. 20ms(excludingcontact bouncetime. (Notfreezingandcondensingat lowtemperature)
Max. side:
3A125VAC, 2A250VAC, 1A30VDC
Max. Usage, StorageandTransport
Conditions”inAMBIENTENVIRONMENT(page626). 20ms(excludingcontact bouncetime,withdiode) (Initial)
Mechanical
characteristics
Shockresistance
Functional 1FormA: 294m/s2,1FormC: 196m/s2
(Half-wavepulseofsinewave: 11ms; detectiontime: 10|as.2mA 810 Q
24VDC 16.7mA Q
9VDC 44.O.25oz
* Specificationswill varywithforeignstandardscertificationratings.
Breakdownvoltage
(Initial)
Betweenopencontacts 1,000Vrmsfor 1min.: 3A(125VAC)
Nominal operatingpower 200mW 400mW
Min.0mm
Expectedlife Mechanical Min