RELAYS Panasonic

| Kategorie: Katalog  | Tento dokument chci!

Panasonic is part of a large worldwide groupselling relays and associated switching products under different brand names in different territories.The conditions of use in some territories may differ from those customary in Europe. In particular there are often major differences in regard to national and international specifications, such as UL, CSA, VDE, SEV, EVE, SEMKO, etc. Thus, when considering contact loads as stated in this catalogue (e.g. 10 A, 30 VDC for the SP relay) its hould be understood that these values are not necessarily an absolute maximum but tested ratings. Mostly the stated value has been tested for a certain life expectancy as stated by the manufacturer or the respective test house. Thus, under different conditions, the stated “maximum” may, in practice, be safely exceeded.

Vydal: Panasonic Electric Works Czech s.r.o. Autor: Panasonic

Strana 514 z 1090

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.







Poznámky redaktora
operating speed 20times/min.2x50|as according JEC-212-1981 *3.) Release time (at nominal voltage) (at 20oC 68oF) (Initial) Max.H.) Destructive 1,000 m/s2(Half-wave pulse sine wave: ms. Refer “6. Usage, Storage and Transport Conditions” inAMBIENT ENVIRONMENT (page 626). Specifications Characteristics Item Specifications Contact Arrangement 1FormA Contact resistance (Initial) Max. Thisvaluecan change duetotheswitchingfrequency, environmental conditions, and desired reliability level, therefore isrecommended tocheckthiswith theactual load. . 100 (By voltage drop 1A) Contact material AgSnO2type Rating Nominal switching capacity (resistive load) 5A277V AC Max.) Vibration resistance Functional 10to double amplitude 1.) Min. (at nominal switching capacity) Unit weight Approx.) Min.5s, OFF: 1.5s, nominal switching capacity) Conditions Conditions for operation, transport and storage*3 Ambient temperature: -40°C +70°C-40°F +158°F, Humidity: 85% R. Point measured: coil inside Contact current: 0A, 8A 3. (excluding contact bounce time. 1,000MQ (at 500V DC) Measurement same location “Breakdown voltage” section. switching capacity (reference value)*1 100mA, DC Electrical characteristics Insulation resistance (Initial) Min. (Detection current: mA) Between contact and coil 4,000 Vrms for 1min. REFERENCE DATA 1.42 oz Notes: *1.5 mm Expected life Mechanical (at 180times/min. Ambient temperature characteristics and coil applied voltage s 10 =5 5 0 100 -►Contactvoltage,V Allowableambienttemperatures against%coilvoltagesI I (max. 106 Electrical (at times/min.5 (Detection time: 10|as. *2. (excluding contact bounce time) (Without diode) Mechanical characteristics Shock resistance Functional 200 m/s2(Half-wave pulse sine wave: ms; detection time: 10|as.LK-T 2. Wave standard shock voltage ±1. Max. switching power (resistive load) 1,385VA Max. (Detection current: mA) Temperature rise (coil) Max. Breakdown voltage (Initial) Between open contacts 1,000 Vrms for 1min. 105(ON: 1. insidethecoiltemperature "setas115°C239°F) 1----1--- Carryingcurrent:5A Coil&contactnocarryingcurrent I ,/ Pick-upvoltage J L 10 80 ►Ambienttemperature,°C 500100 400 300 200 100 0 00 312 61B13 Ikt: 290212J . switching current (AC) Min. switching power (AC resistive load) Coil temperature rise Sample: LKT1aF-12V, pcs. switching voltage 277V AC Max. The upper operation ambient temperature limit isthe maximumtemperature that can satisfy the coil temperature rise value. 35°C 95°F (By resistive method, nominal coil voltage applied the coil; contact carrying current: 5A, 70°C 158°F) Surge breakdown voltage*2 (Between contact and coil) (Initial) 10,000V Operate time (at nominal voltage) (at 20oC68oF) (Initial) Max. (Not freezing and condensing lowtemperature), Air pressure: 106kPa Max.) Destructive 10to double amplitude 1