RELAYS Panasonic

| Kategorie: Katalog  | Tento dokument chci!

Panasonic is part of a large worldwide groupselling relays and associated switching products under different brand names in different territories.The conditions of use in some territories may differ from those customary in Europe. In particular there are often major differences in regard to national and international specifications, such as UL, CSA, VDE, SEV, EVE, SEMKO, etc. Thus, when considering contact loads as stated in this catalogue (e.g. 10 A, 30 VDC for the SP relay) its hould be understood that these values are not necessarily an absolute maximum but tested ratings. Mostly the stated value has been tested for a certain life expectancy as stated by the manufacturer or the respective test house. Thus, under different conditions, the stated “maximum” may, in practice, be safely exceeded.

Vydal: Panasonic Electric Works Czech s.r.o. Autor: Panasonic

Strana 485 z 1090

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.







Poznámky redaktora
switching current (AC) Min. (excluding contact bounce time) (With diode) Mechanical characteristics Shock resistance Functional 200 m/s2(Half-wave pulse sine wave: ms; detection time: 10|as. operating speed times/min. (By voltage drop 1A) Max. itching power (AC resistive load) 2-(1). 5x104(ON: OFF=1.5 (Detection time: 10|as.H.) Release time (at nominal voltage) (at 20°C 68°F) Max. Life curve (250 resistive load) for 2-(2). Max. switching voltage 125VAC 277V AC Max. (excluding contact bounce time.) Destructive double amplitude 1. 106(at 180 times/min. switching power (resistive load) 625VA 1,385VA Max. Life curve (125 resistive load) for 5A type type A 2 / P 2 A 12 1 0 C A 1 0 5 3 0 ds 61B09 la: 070313D 283 Power .2x50p,s according JEC-212-1981 *3. (Detection current: mA) Between contact and coil 4,000 Vrms for 1min. 100 (By voltage drop 1A) Contact material Gold-clad, AgNi type AgSnO2type Rating Nominal switching capacity (resistive load) 125VAC 277VAC Max. The upper limit ofthe ambient temperature isthe maximumtemperature that can satisfy the coil temperature rise value. This value can change dueto the switching frequency, environmental conditions, and desired reliability level, therefore recommended checkthis with the actual load. Wave standard shock voltage ±1. (Detection current: mA) Temperature rise (coil) Max.) Vibration resistance Functional double amplitude 1. 45°C 113°F (with nominal coil voltage and contact carrying current, 70°C 158°F) Surge breakdown voltage*2 (Between contact and coil) (Initial) 10,000 V Operate time (at nominal voltage) (at 20°C 68°F) Max. switching capacity*1 100mA5V DC Electrical characteristics Insulation resistance (Initial) Min.5s) (at nominal switching capacity) Conditions Conditions for operation, transport and storage*3 Ambient temperature: -40°C +70°C 40°Fto +158°F, Humidity: 5to 85% R. (at nominal switching capacity) Unit weight Approx. (Detection current: mA) Between open contacts 1,000 Vrms for 1min.) Destructive 1,000 m/s2(Half-wave pulse sine wave: ms. Breakdown voltage (Initial) Between contact sets 1,000 Vrms for 1min. *2.(ALA) 2.) Min.46 oz Notes: *1. 45°C 113°F (with nominal coil voltage and contact carrying current, 70°C 158°F) Max. 1,000MQ (at 500V DC) Measurement same location “Breakdown voltage” section.) Electrical (at times/min. Usage, Storage and Transport Conditions” inAMBIENT ENVIRONMENT (page 626). (Not freezing and condensing lowtemperature), Air pressure: 106kPa Max. Specifications Characteristics Item Specifications 3Atype TVtype (TV-4) Contact Arrangement FormA Contact resistance (Initial) Max. Refer “6.5s: 1. REFERENCE DATA 1.5 mm Expected life Mechanical Min.