RELAYS Panasonic

| Kategorie: Katalog  | Tento dokument chci!

Panasonic is part of a large worldwide groupselling relays and associated switching products under different brand names in different territories.The conditions of use in some territories may differ from those customary in Europe. In particular there are often major differences in regard to national and international specifications, such as UL, CSA, VDE, SEV, EVE, SEMKO, etc. Thus, when considering contact loads as stated in this catalogue (e.g. 10 A, 30 VDC for the SP relay) its hould be understood that these values are not necessarily an absolute maximum but tested ratings. Mostly the stated value has been tested for a certain life expectancy as stated by the manufacturer or the respective test house. Thus, under different conditions, the stated “maximum” may, in practice, be safely exceeded.

Vydal: Panasonic Electric Works Czech s.r.o. Autor: Panasonic

Strana 438 z 1090

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.







Poznámky redaktora
80°C (By resistive method, nominal voltage) Operate time (at 20°C )*2 DCtype/AC type: Max. continuous current. Breakdown voltage (Initial) Between open contacts 1,000 Vrmsfor 1min. For use with 200V DC, connect (5W) resistor, series, the 100V relay. 5x105 2 Form 10A 250VAC resistive load (cos9=1) Life switching cycle: Min. 3x105 DC load 1Form 30V resistive load (cos9=1) Life switching cycle: Min. Refer “6.9 650 nominal voltage nominal voltage 48V 18.2 (Initial) (Initial) 23.) Destructive Min. Coil data 1) ils Nominal coil voltage Nominal coil current (mA) Nominal operating power (VA) Pick-up voltage (at 20°C 68°F) Drop-out voltage (at 20°C 68°F) Inductance (H) Max. Operating speed times/min. Inparticular, forACoperation, iftheappliedvoltagedropsto80%Vormore belowthe ratedvoltage, hummingwill occurand alargecurrentwill flowleading possibly to coil burnout. (Not freezing and condensing lowtemperature) Max. (This value differs depending the ambient temperature. Thisvalue not permissiblevaluefor continuous operation. (Detection current: 10mA. 2.) Destructive double amplitude mm Expected life Mechanical type: 5x107 (at 180times/min. Thisvalue not permissible valuefor continuous operation. 196 m/s2(Half-wave pulse sine wave: ms; detection time: 10|as. 25ms (Nominal voltage applied the coil, excluding contact bounce time. Specifications Characteristics Item Specifications Contact Initial contact resistance, max Max. *1This value can change due the switching frequency, environmental conditions and desired reliability level, therefore recommended checkthis with the actual load.145 100/110VAC 13. 5.078 0.5 10.) Between contact sets 1,500 Vrmsfor 1min.) Between contact and coil 2,000 Vrmsfor 1min. 5x105 2 Form 30V resistive load (cos9=1) Life switching cycle: Min. The relay operates range 80%to 110%V the voltage rating, but ideally, consideration temporary voltage fluctuations, should operated the rated voltage.074 12VAC 111 100 0.181 110%Vof nominal voltage 48VAC 1. switching capacity (Reference value)*1 100mA DC Electrical characteristics Insulation resistance (Initial) Min.) Electrical AC load 1Form 15A 125VAC, 10A 250VAC resistive load (cos^=1) Life switching cycle: Min.23 oz Notes: If integrating into electrical appliances that will subject compliance the Electrical Appliance and Material Safety Law, please use ambient temperature between -50°C +40°C-58°F +104°F (ACtype).243 1.), type: 108(at 180times/min.H. The coil resistance for operation isthe value measured when the coil temperature is20°C 68°F. 25ms (Nominal voltage applied the coil, excluding contact bounce time. 2.312 0.7/7.7 12/13.75 20. 3.0 10,000 Notes: The rated excitation current is±10% (20°C 68°F).2 nominal voltage nominal voltage 4. The maximum allowablevoltage isthe maximumvoltagefluctuation value forthe coil power supply.) Vibration resistance Functional double amplitude (Detection time: 10|as.9/11.9 2,600 (Initial) (Initial) 100/110V 1.) 2. 236 61C03 hl: 080413J . (at max. applied voltage 50Hz 60Hz 50Hz 60Hz When drop-out When operating 6V 224 200 0.) 2 ils ) Nominal coil voltage Nominal coil current (mA) Nominal operating power (W) Coil resistance (Q) Pick-up voltage (at 20°C 68°F) Drop-out voltage (at 20°C 68°F) Max.4 6/6. *3 The upper operation ambient temperature limit isthe maximumtemperature that can satisfy the coil temperature rise value. 35g 1.98 81. 100MQ (at 500V DC) Measurement same location “Initial breakdown voltage” section. Please contact usfor details.) Release time (at 20°C )*2 DCtype/AC type: Max.19 25. (Detection current: 10mA. (Byvoltage drop 1A) Contact material AgSnO2type Rating Nominal switching capacity 1Form 15A 125VAC, 10A 250VAC (resistive load) 2 Form 10A 125VAC (resistive load) Min. The maximum allowablevoltage isthe maximumvoltagefluctuation valueforthe coil power supply.2/13.76 Notes: The relay operates range 80%to 110%V the voltage rating, but ideally, consideration temporary voltage fluctuations, should operated the rated voltage.974 4.9 27.) Temperature rise Max. 980 m/s2(Half-wave pulse sine wave: ms. Usage, Storage and Transport Conditions” inAMBIENT ENVIRONMENT (page 626).63 110/120VAC 12.6 85.9 40 12V 0. (Detection current: 10mA.3 1. *4 When using the socket, sure verify the max.57 200/220VAC 6.4/14.5 0. 4. applied voltage (at 70°C 158°F) 6V 150 0. *2For the coil types, the operate/release time will differ depending the phase.4% for every ±1°C change intemperature. 5x105 Conditions Conditions for operation, transport and storage*3 Ambient temperature: -50°C +70°C-58°F +158°F (Without LED indication); -50°C +60°C-58°Fto +140°F (With LED indication) Humidity: 5to 85% R. Compensate ±0. (This value differs depending the ambient temperature.295 24VAC 80%V less 30%V more 1.HL RATING 1.) (without diode) Mechanical characteristics Shock resistance Functional Min.9 160 80%V less 10%V more 110%V of nominal voltage 24VDC 0. rating) Unit weight Approx. Please contact usfor details