Panasonic is part of a large worldwide groupselling relays and associated switching products under different brand names in different territories.The conditions of use in some territories may differ from those customary in Europe. In particular there are often major differences in regard to national and international specifications, such as UL, CSA, VDE, SEV, EVE, SEMKO, etc. Thus, when considering contact loads as stated in this catalogue (e.g. 10 A, 30 VDC for the SP relay) its hould be understood that these values are not necessarily an absolute maximum but tested ratings. Mostly the stated value has been tested for a certain life expectancy as stated by the manufacturer or the respective test house. Thus, under different conditions, the stated “maximum” may, in practice, be safely exceeded.
RATING
Specifications (Sockets
Item Performance
Type
HC1
Plug in
terminal socket
HC1
PC board
socket
HC2
Plug in
terminal socket
HC2
PC board
socket
HC3
Plug in
terminal socket
HC3
PC board
socket
HC4
Plug in
terminal socket
HC4
PC board
socket
Contact arrangement Form (1-pole) Form (2-pole) Form (2/3-pole common) Form (1/2/4-pole common)
Max.
202 61C04 hc: 110313J
. continuous
current (7A). continuous current
(Ambient temperature:
-50 +700C -58 +1580F)
7A 7A
Breakdown
voltage
(Initial)
Between open
contacts
Between contact
sets
2,000 Vrms for min.
• •
HJ2-terminal socket
(Finger protect type)
HJ2-SFD-S •
1/2/4-pole
(common)
HJ4-terminal socket HJ4-SFD •
HJ4-terminal socket
(Finger protect type)
HJ4-SFD-S •
Note: When using HJ4-SFD/HJ4-SFD-S with relay Form C/2 Form set, please keep the terminal socket max.HC
3. continuous current higher than A. (Detection current: 10mA)
Between contact
and coil
Initial insulation resistance 100 between each terminal (500V DC)
Note: When using 1/2 pole relay (10A, rating) Form socket that 1/2/4-pole common, please use within range that does not exceed the max.
100
pcs. pole Item Part No.
Specifications (Terminal sockets)
Item Performance
Type
HC2-slim
For DIN rail
terminal
sockets
HC2
For DIN rail
terminal
sockets
HC2
For general
terminal
sockets
HC3
For DIN rail
terminal
sockets
HC3-high
For general
terminal
sockets
HC4-high
For DIN rail
terminal
sockets
HC4-high
vertical type
terminal
sockets
HC4
For general
terminal
sockets
Contact arrangement Form (2-pole) Form (2/3-pole common) Form (1/2/4-pole common)
Max. continuous
current (5A).
Standard
packing
Applicable relay (Plug-in type)
Standard type/With diode type (for DC) Amber type
Carton Case Form Form Form C
4 Form C
(twin)
1 Form Form Form C
4 Form C
(twin)
For
DIN rail
2-pole
HJ2-terminal socket HJ2-SFD
10 pcs. Terminal sockets (HJ relay terminal sockets)
Type No. continuous current
(Ambient temperature:
-50 +700C -58 +158°F)
10A 10A 5A
Breakdown
voltage
(Initial)
Between open
contacts
Between contact
sets
2,000 Vrms for min. (Detection current: 10mA)
Between contact
and coil
Initial insulation resistance 100 between each terminal (500V DC)
Note: When using 1-pole relay (10A) Form terminal socket that 1/2/4-pole common, please use within range that does not exceed the max