Panasonic is part of a large worldwide groupselling relays and associated switching products under different brand names in different territories.The conditions of use in some territories may differ from those customary in Europe. In particular there are often major differences in regard to national and international specifications, such as UL, CSA, VDE, SEV, EVE, SEMKO, etc. Thus, when considering contact loads as stated in this catalogue (e.g. 10 A, 30 VDC for the SP relay) its hould be understood that these values are not necessarily an absolute maximum but tested ratings. Mostly the stated value has been tested for a certain life expectancy as stated by the manufacturer or the respective test house. Thus, under different conditions, the stated “maximum” may, in practice, be safely exceeded.

Vydal: Panasonic Electric Works Czech s.r.o. Autor: Panasonic

Strana 264 z 1090

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.







Poznámky redaktora
Coil data Single side stable type Nominal coil voltage Pick-up voltage (at 20oC 68°F) Drop-out voltage (at 20oC68oF) Nominal operating current [+10%] (at 20oC68oF) Coil resistance [+10%] (at 20oC68oF) Nominal operating power Max. (Detection current: 10mA.) Between contact sets 1,000 Vrms for 1min.) Release time [Reset time] (at 200C680F) Approx. 200 mW(300 mW: V) Electrical characteristics Insulation resistance (Initial) Min. 108 Electrical 5x105(1 30V DC), 105(2 30V DC) Conditions Conditions for operation, transport and storage* Ambient temperature: -400C +700C Humidity: 85% R.7mA 45Q 5V 40mA 125Q 6V 33. [approx. 490 m/s2(Half-wave pulse sine wave: ms; detection time: 10|as. (Detection current: 10mA.3mA 7,680Q 300mW 2. Usage, Storage and Transport Conditions” inAMBIENT ENVIRONMENT (page 626).14oz * Refer “6. carrying current A Minimum operating power Approx. Unit weight Approx. .5V DC 70%V less of nominal voltage (Initial) 10%V more of nominal voltage (Initial) 132.7mA 11.) Destructive 10to double amplitude mm Expected life Mechanical Min. applied voltage (at 50oC 122oF) 1. 980 m/s2(Half-wave pulse sine wave: ms. Max.) FCC surge breakdown voltage between contacts and coil 1,500 V Temperature rise (at 200C 68°F) Max. (By voltage drop 1A) Contact material Ag+Au clad Rating Max. (Not freezing and condensing lowtemperature) Max.3mA 2,880Q 48V 6. switching voltage 220 DC, 250 VAC Max.) Destructive Min.) (without diode) Mechanical characteristics Shock resistance Functional Min.3 (Detection time: 10|as. 62 ds_61005_en_ds2y: 210113J . 650Cwith nominal coil voltage across coil and nominal switching capacity Operate time [Set time] (at 200C680F) Approx. 100MQ (at 500V DC) Measurement same location “Initial breakdown voltage” section.) Vibration resistance Functional 10to double amplitude 3.3mA 180Q 9V 22.) Between contact and coil 1,000 Vrms for 1min. ms] (Nominal coil voltage applied the coil, excluding contact bounce time.5 (resistive load) Max. [approx.H. operating speed (at rated load) times/min. mW(147 mW: 48V) Nominal operating power Approx. Breakdown voltage (Initial) Between open contacts 750Vrmsfor 1min. switching current A Max.DS2Y RATING 1.3Q 200mW 200%V of nominal voltage 3V 66. ms] (Nominal coil voltage applied the coil, excluding contact bounce time. switching power 62.7mA 720Q 24V 8. Specifications Characteristics Item Specifications Contact Arrangement Form C Initial contact resistance, max. (Detection current: 10mA.2mA 405Q 12V 16