RELAYS Panasonic

| Kategorie: Katalog  | Tento dokument chci!

Panasonic is part of a large worldwide groupselling relays and associated switching products under different brand names in different territories.The conditions of use in some territories may differ from those customary in Europe. In particular there are often major differences in regard to national and international specifications, such as UL, CSA, VDE, SEV, EVE, SEMKO, etc. Thus, when considering contact loads as stated in this catalogue (e.g. 10 A, 30 VDC for the SP relay) its hould be understood that these values are not necessarily an absolute maximum but tested ratings. Mostly the stated value has been tested for a certain life expectancy as stated by the manufacturer or the respective test house. Thus, under different conditions, the stated “maximum” may, in practice, be safely exceeded.

Vydal: Panasonic Electric Works Czech s.r.o. Autor: Panasonic

Strana 159 z 1090

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.







Poznámky redaktora
Ex. Use within the range indicated the graph below. 10) Avoid mounting the relay strong magnetic fields (near a transformer magnet) close object that radiates heat.2 2. 2. 3) Atmospheric pressure: 106 kPa Temperature and humidity range for usage, transport, and storage i Humidity, %RH 85- I Tolerance range I When continually powered DC / / /(Avoid freezing (Avoid / /When used condensation , /temperatures when used at flower than temperatures /0°C 32°F) higher than '//A 0°C 32°F) // i i -40 -40 0 +32 65 80 +149+176 Temperature, °F 4) Condensation Condensation forms when there sudden change in temperature under high temperature and high humidity conditions.0 Nm, Horizontal type (M4 screw): 2. the contact terminals were connected with opposite pole, the electric life would shorter. 5) Low temperature, low humidity environments The plastic becomes brittle the relay exposed low temperature, low humidity environment for long periods time. Please avoid such usage.) The humidity range varies with the temperature. Insertion strength into the tab terminal: Max. This causes the pick-up voltage rise, and possibly exceed the rated pick-up voltage. 2) Additionally the ambient temperature and condition for your application should considered because pick-up and drop-out voltage will changed. V Ex. Usage, transport and storage conditions 1) Temperature: +80°C -40 +176°F (-40 +65°C -40 to +149°F when continually powered DC) 2) Humidity: 85% (Avoid freezing and condensation. When using varistor Recommended Varistor; Maximum Energy: more than 1J (However, please make settings using values that take into consideration the worst case scenario. 6) the relay used while exceeding the coil rating, contact rating cycle lifetime, this may result the risk overheating. these circumstances, take measures such reducing the load current, limiting the duration current flow, and applying coil voltage higher than the rated operating voltage (quick start). Cautions for Use 1) Regarding cautions for use and explanation technical terms, please refer our general catalog. 5) When applying current which includes precipitous changes or ripple, the relay may generate buzzing sound.8mm . Condition tightening screw 1) Tightening torque for fixing relay-body; Vertical and Horizontal type (M5 Screw): 3.0 4. 13) the power turned off and then immediately after applying the rated voltage (current) continuously the relay's coil and contact, the resistance the coil will increase due a rise the coil temperature.) Varistor voltage: For input, Min.5 times more (at least for rated type) the rated operation voltage. 9) When the screws for fixing relay-body and for additional terminal are tightened, should used within the range of decided torque. If only diode connected parallel with the relay coil, the contact opening velocity will become slow and sufficient cutoff performance cannot guaranteed. Especially, Contact terminals have polarity. 12) The relay contacts are encapsulated inert gas atmosphere. (temperature 35°C 95°F, humidity 25%RH to 85%RH) Lifetime dependent the coil driving circuit, load type, operation frequency and ambient conditions.10N (for vertical type) 4. Care must exercised when the relay be used stored high ambient temperature., that the clamp voltage reaches 1.031inch and #250 tab terminal 5. 11) the several relays are mounted closely heat- generation object close the relay, take care check the abnormal temperature-rise and the insulation distance between the terminals outside the relay. When using zener diode (circuit) ZD18V+ Diode voltage f Clamp voltage ZD30V Zener voltage 30V-12V=18V Clamp voltage 4) Lifetime specified under the standard test conditions JIS C 5442. 3) includes ripple, the ripple factor should less than 5%.0 4. 8) Take care avoid cross connections they may cause malfunctions overheating. Allowable pulling force for the coil input lead wire: Max. 7) general rule, not use relay has been dropped. 49N (for horizontal type) Reference: Please select faston terminal (flat connection terminal) which comply with JIS C2809-1999. 158 ds_61213_en_ev_quiet: 010312D . For coil surge absorption, please use zener diode varistor, etc. Condensation will cause deterioration the relay insulation.8 m 3. Check lifetime under the actual condition.0 m 2) Tightening torque for contact terminal; Vertical type (M5 screw): 3. For plate thickness 0.(AEVS) NOTES 1. Therefore, please confirm with the actual load