Modular Terminal Blocks Catalogue 2012/2013

| Kategorie: Katalog  | Tento dokument chci!

Terminals, P-Series (PUSH IN technology) Terminals, Z-Series (Tension clamp technology) Terminals, W-Series, Stud terminals, SAK-Series (Screw connection technology) Shield connection terminals KLBÜ AccessoriesAppendix

Vydal: Weidmüller, s.r.o. Autor: Weidmueller

Strana 532 z 571

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.







Poznámky redaktora
Maintaining the rated insulation voltage The required stripping length is specified for every Weidmüller product. ensure that the electrical components have been disconnected from the power supply, the following five safety rules must be adhered before carrying out any W Technicalappendix W. Partition plate A partition plate required create a visual distinction between electric circuits, ensure electrical isolation between neighbouring cross- connections. These lengths, e.5 mm, mm, must be maintained. Separation plate Separation plates can retrofitted between cross-connections sockets on modular terminals terminal width max.5. Combinations various terminals • Always fit end plate partition plate (WAP/TW, ZAP/TW and IAP) at changes profile. • End brackets can omitted adjacent terminals, with the exception WDK/PE and ZPE + WPE 1.20 1282250000 2012/2013 .Installation instructions The installation terminal strips Assembly and end brackets • Assemble terminal strips from left to right.5 3. mounting tolerance 0. • Always close off the open side a modular terminal with end plate or partition plate (WAP/TW, ZAP/ TW and IAP).g. Working electrical connections with non-insulated screwdrivers The use non-insulated screwdrivers is only permitted electrical systems that have been isolated. • Closed side the left, open the right. This also applies when using wire end ferrules.2 the specified terminal width should allowed for in the planning. • When terminal required adjacent between associated feed-through terminals the same series and size, the rated voltage and rated impulse withstand voltage of the feed-through terminals are not affected. • Fit end brackets both ends a terminal strip. mm. 0. Dimensions The dimensions specified are those of the enclosing housing the modular terminal, including fixing components but excluding tolerances. The outside dimensions crimped wire end ferrules must comply with IEC 60947-1, 1999 edition. • Always fit end plates partition plates (WAP/TW, ZAP/TW and IAP) between adjacent terminals with different rated voltages order to maintain the respective voltages