MEATEST: Uživatelské příručky kalibračních měřidel

| Kategorie: Návody k obsluze  | Tento dokument chci!

Vydal: Meatest, spol. s r.o. Autor: MEATEST

Strana 792 z 1270

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.







Poznámky redaktora
Calibration points Each function the calibrator has assigned fixed calibration points which have set during the calibration. Both complete and partial calibration possible. Calibrator returns the last selected function. s. Use rotary button move the cursor through the list. 2. Output terminals are automatically switched on at the same time ready for measuring the selected calibration point. New calibration value saved immediately when ENTER button rotary button pushed for new value confirmation.o.r. • Connect RCL standard meter when capacitance calibration point beingcalibrated andwrite down new resistance value. Selection and setting ofcalibration point After the calibration menu displayed, one partial calibrations can selected.5 kQ. • When built mA-meter calibrated, connect current requested valuefrom standard unit and confirmwith ENTER button rotary button save new calibration data. • When built kV-meter calibrated, connect voltage requested value fromstandard unit and confirmwith ENTER button rotary button save new calibration data.M191 Insulation Tester Calibrator MEATEST. Having selected the required function calibrated, press the rotary button ENTER button enable the calibration value right column for editing. Confirm with ENTER button rotary button. The original calibration value refreshed. When only some calibration points are changed, all other non­ changed calibration points are stored with original data. Calibration process can interrupted left any time pushing the button SETUP. Confirm with ENTER button rotary button. Input resistance internal mA-meter approx. • Measure the resistance value using standard ohmmeter when resistance segment calibrated and write down new resistance value. Go next requested calibration point. Standard current source with compliance voltagemin. List calibration points includes: • Single resistance segments summary range from 1TQ, R00 R45 • Single capacitors 10, 50, 100 nF, C00 C02 • voltage 5000 V00 and V01 • current mA, I00 and I01 28 User Manual . When change the calibration value requested push the rotary button ENTER button once more. 15Vhas tobeapplied. Note: When resistance points are calibrated two-terminals way connection the calibrator tostandard ohmmetershouldbeapplied