5. Strip cable above - Note: Trim cable tails double over for better terminal contact. 2. 4. 6. Refit cover. Push outer sheath cable firmly into jaws sheath grip, making sure that least 2mm of sheath protrudes below the grip. Lighting, Connection & Control Klik 4 Wiring 5mm 40mm 5mm 2mm 1. Pass cable through plug cover centre hole. Luminaire PCR2000 Functional Switch LOOP Functional Switch Functional Switch Two Circuit Luminaire CR64AX LOOP Emergency Luminaire Functional Switch Functional Switch CR64AX LOOP Battery Inverter Note: earth connections omitted for clarity . Terminate conductors into terminals.41 Data subject errors and technical modifications. Remove plug cover. 3