Multiple settings can stored in Memo and Memo and re-called set several devices. press and 5’ for time value 7’ Day level 1000 Lux LED set the value 1000 Lux Learn LED learn the current Lux level Corridor 200 Lux LED set the value 200 Lux Office 400 Lux LED set the value 400 Lux Lux LED increase the Lux level (+100) Lux LED decrease the Lux level (-100) Active cell Green LED The light continuously measured Passive cell RED LED The sensor will not switch the light off even the ambient luminosity sufficient Memo and set Key Meaning Indication Function Press LED until setting changed load/unload Memo 1 Long press LED for 5s, then will blink until released. After release, the LED goes off in case setting change To save the current setting Memo 1 Press LED until setting changed load/unload Memo 2 Long press LED for 5s, then will blink until released. In the case opposite states the green LED denotes ON and red LED denotes OFF (except Presence / Absence). When function selected all LED’s are OFF. The SET key used send the messages the occupancy sensors. When the potentiometer is on auto test allows single and multiple settings.Data subject errors and technical modifications. Single setting Example: reset Multiple settings Define the parameters changed and press SET to send. + + + + . Lighting, Connection & Control Klik IR Commissioning Remote Control (EEK001) Settings available Key Meaning Indication Function Presence Green LED Presence (automation mode) Absence Red LED Absence (semi automatic mode) Power Green LED The light automatically switched for seconds after power up Red LED During warm phase, the light output off Reset LED return factory settings (Lux 400, time min, presence on, power off and cell active) Test LED validate the detection area Time LED set the time It possible add times together e.g. Example: for minutes and corridor use, press 20’, 5’ and corridor. Technical specification Power supply:1x CR2032 Shelf life battery: years Protection index: 30 LED The acknowledgment LED blinks during the sending the IR message. After release, the LED goes off in case setting change To save the current setting Memo 2 Short press (<5s) LED flashes send message the current setting Long press (>5s but <10s) only available setting active LED blinks until release press toggle automatic mode DALI/DSI Use The remote control allows the user set modify presence detector settings