High Voltage Cable Systems Cables and Accessories up to 550 kV

| Kategorie: Leták / Datasheet  | Tento dokument chci!

Development, consultancy, planning and design, cost-optimization, production, logistics, installation and service. With this all-round support the nkt cables HV-team will be at ourcustomer’s service in regard of the products high voltage and extra-high voltage cables and accessories. Optimized internal communication systems, specialized divisions and intensively trained team members are the power behind the customer-orientated installation solutions. With competence and know-how the nkt cables “Power Team” provides secure and reliable power supply wherever fully developed high-voltage power transmission is ...

Vydal: nkt cables s.r.o. Autor: nkt cables

Strana 10 z 32

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.







Poznámky redaktora
30 Bending radius during laying min. /km 0,0221 0,0176 Al conductor max. 3,15 3,15 at terminations min. 128 130 133 136 139 143 150 Cable weight (Cu/Al) approx. kV/mm 14,9 14,8 at core screen approx. mH/km 0,45 0,43 Current Ratings/Power Ratings (continuous load) trefoil installation Cu conductor cables circuit A/MVA 628/544 661/572 2 circuits A/MVA 498/431 520/450 Al conductor cables circuit A/MVA 537/465 577/500 2 circuits A/MVA 427/370 455/394 Type (A)2XS(FL)2Y RMS/170 290/500 with segmental conductor (RMS) Dimensions/Cross Sections mm² 1000 1200 1400 1600 1800 2000 2500 Conductor, round, stranded, segmental, approx. kg/m 15 Permissible pulling force (Cu/Al) max. /km 0,0492 0,0401 Field strength U0 at conductor screen approx. kg/m 23 Permissible pulling force (Cu/Al) conductor max. /km 0,0375 0,0319 0,0275 0,0240 0,0213 0,0193 0,0156 Field strength U0 at conductor screen approx. 35,0 33,0 Screen, copper wire, cross section nom. 39,0 42,0 45,3 48,5 51,3 54,3 60,9 XLPE insulation nom. mm² 170 170 170 170 170 170 170 Outer diameter approx. /km 0,0367 0,0291 Cu conductor resistance 90°C approx. kV/mm 5,1 5,6 Capacitance per core approx. 32,0 31,0 31,0 31,0 31,0 31,0 31,0 Screen, copper wire, cross section nom. 1,90 1,90 Electrical Data Cu conductor resistance 20°C max. µF/km 0,124 0,137 Inductance approx. 34,2 38,1 XLPE insulation nom. /km 0,0176 0,0151 0,0129 0,0113 0,0101 0,0090 0,0072 Al conductor max.10 500 Single Core XLPE Cables with Copper Wire Screen and APL Sheath Type (A)2XS(FL)2Y RM/170 290/500 with stranded compacted conductor (RM) Dimensions/Cross Sections mm² 800 1000 Conductor, Al, round, stranded, approx. 1,95 1,95 2,00 2,05 2,10 2,15 2,25 Electrical Data Cu conductor resistance 20°C max. 100 125 75 Bending radius during laying min. /km 0,0291 0,0247 0,0212 0,0186 0,0165 0,0149 0,0119 Cu conductor resistance 90°C approx. /km 0,0315 0,0265 Al conductor approx. µF/km 0,149 0,159 0,167 0,174 0,180 0,187 0,202 Inductance approx. /km 0,0232 0,0201 0,0175 0,0156 0,0142 0,0129 0,0109 Al conductor approx. 126 126 Cable weight (Cu/Al) approx. kV/mm 14,6 14,6 14,3 14,1 13,9 13,6 13,3 at core screen approx. mm² 170 170 Outer diameter approx. kV/mm 6,0 6,3 6,4 6,5 6,6 6,7 6,8 Capacitance per core approx. 3,20 3,25 3,35 3,40 3,50 3,55 3,75 at terminations min. mH/km 0,56 0,55 0,53 0,52 0,51 0,50 0,47 Current Ratings/Power Ratings (continuous load) flat installation Cu conductor cables circuit A/MVA 907/785 968/838 1031/896 1085/896 1124/973 1159/1004 1226/1062 2 circuits A/MVA 770/667 818/708 868/752 912/790 942/816 969/839 1019/882 Al conductor cables circuit A/MVA 725/628 782/677 838/726 893/773 939/813 976/845 1063/921 2 circuits A/MVA 615/533 661/572 707/612 751/650 787/682 816/707 884/766