1 GOhm km
Insulation resistance, min.:
+80°C
Operating temperature range max. DIN 19245 and EN50170
Applicable standards:
Flame-retardant acc. kg/km
Weight:
80 mm
bending radius, repeated:
-20°C
Operating temperature range min. With its core design and the special PVC sheath, the type
described here suitable for normal mobile applications.:
173 Ohm/km max.
Dimensions and specifications may changed without prior notice.:
1,20 MJ/m
Caloric load, approx.
708
Data, Network and Bus Technology HELUKABEL BUS-Cables
®
.64 (stranded)
Cable structure
Copper, bare (AWG 24/7)
Inner conductor diameter:
Foam-skin-PE
Core insulation:
rd, gn
Core colours:
2 cores fillers stranded together
Stranding element:
Polyester foil over stranded bundle
Shielding 1:
Polyester foil, aluminium-lined
Shielding 2:
Cu braid, tinned
Total shielding:
PVC
Outer sheath material:
app. 7,8 0,3 mm
Cable external diameter:
Violet similar RAL 4001
Outer sheath colour:
Electrical data
150 Ohm %
Characteristic impedance:
86,7 Ohm/km
Conductor resistance, max. 50265-2-1
UL Style 2571
UL Style:
Application
HELUKABEL® Profibus 7-wire for mobile applications Profibus industrial networks.
Mutual capacitance:
1,5 kV
Test voltage:
Attenuation: dB/km
3,0
<
kHz
9,6
dB/km
5,0
<
kHz
38,4
dB/km
26,0
<
MHz
4
dB/km
55,0
<
MHz
16
Technical data
app.
800648, Profibus L2
Part no.
Loop resistance:
30 nF/km nom.BUS Cables
Profibus L2
7-wire
Mobile use
Type
1x2x0. value:
24,00 kg/km
Copper weight:
Norms
Profibus acc