to the sheath, also offers excellent resistance common mineral oils, greases and cooling lubricants. value:
31,00 kg/km
Copper weight:
Norms
Acc.:
250 Ohm/km max. EN50267-2-3, AWM 20963 (80°C/30V)
Application
HELUKAT® 100S Cat drag chain Eco designed for use cable carriers and the recurring loads caused moving machine components.
Dimensions and specifications may changed without prior notice.
82839, INDUSTRIAL ETHERNET CAT.:
0,64 MJ/m
Caloric load, approx. kg/km
Weight:
102 mm
bending radius, repeated:
-40°C
Operating temperature range min.15 mm² (stranded)
Cable structure
Copper, bare (AWG 26/19)
Inner conductor diameter:
PO
Core insulation:
whbu/bu, whog/og, whgn/gn, whbn/bn
Core colours:
Double core
Stranding element:
-
Shielding 1:
PETP fleece
Shielding 2:
Foil braid
Total shielding:
PUR
Outer sheath material:
app.
Loop resistance:
48 nF/km nom.:
+80°C
Operating temperature range max. ISO/IEC 11801, Acc. IEC 60332-1, Halogen-free acc.
Mutual capacitance:
0,5 kV
Test voltage:
67 %
Relative propagation velocity:
Typical values
155
100
62,5
16
10
(MHz)
Frequency
41,0
32,0
24,8
12,1
9,5
(db/100m)
Attentuation
30,0
35,3
38,5
48,0
50,0
(db)
Next
Technical data
app.100S
Industrial Ethernet
Drag chain ECO
SF/UTP 4-pair, Category 5e
Drag chain applications
Type
SF/UTP 4x2x0.5e
Part no. 60754-2,
Corrosiveness acc. EIA/TIA 568-A, Category 5e, Flame-retardant acc.
695
R
Data, Network and Bus Technology HELUKABEL BUS-Cables
®
. 50173, Acc. 6,6 0,2 mm
Cable external diameter:
Green
Outer sheath colour:
Electrical data
100 Ohm ohm 100 MHz
Characteristic impedance:
5 GOhm km
Insulation resistance, min