+60°C
Operating temperature range max. 6,3 mm
Outer diameter:
Grey
Outer sheath colour:
Electrical data
100 Ohm ohm 100 MHz
Characteristic impedance:
100 Ohm Ohm 101 300 MHz
190 Ohm/km max.
Loop resistance:
50 nF/km nom.
to IEC 60332-1, Smoke density acc. EIA/TIA 568-A, Category Flame-retardant acc. propagation velocity:
Typical values
300
200
155
100
62,5
16
10
(MHz)
Frequency
32,5
26,0
22,9
18,2
14,3
7,0
5,6
(db/100m)
Attenuation
55,0
57,0
60,0
63,0
65,0
70,0
72,0
(db)
Next
22,5
31,0
37,1
44,8
50,7
63,0
66,4
(db)
ACR
Technical data
app. They can used implement services such Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s, ISDN absolutely trouble-free. This type certified according because the special PVC jacket
802172, U/UTP 4x2xAWG24/1 PVC (UTP)
Part no. IEC 61034, CMX 444
Application
HELUKAT®300 data cables are used the tertiary, but also the secondary level network. kg/km
Weight:
55 mm
bending radius, repeated:
-20°C
Operating temperature range min.
656
Data, Network and Bus Technology HELUKAT Copper data cables
®
. value:
20,00 kg/km
Copper weight:
Norms
Acc. Likewise, the mechanical characteristics are perfectly suited for the application tight cable channels
and platforms due their optimized construction. They are characterized large performance reserves
and outstanding performance.300
LAN Cable
Category 6
U/UTP UL
U/UTP 4x2xAWG 24/1 PVC, UL
Cable structure
0,55 mm
Inner conductor Ø:
Copper, bare
Conductor material:
PE
Core insulation:
whbu/bu, whog/og, whgn/gn, whbn/bn
Core colours:
Polyester foil over stranded bundle
Shielding 1:
-
Screen over stranding element:
-
Screen over stranding:
-
Screen over stranding:
PVC
Outer sheath material:
app. ISO/IEC 11801, Acc.
Dimensions and specifications may changed without prior notice.:
0,68 MJ/m
Caloric load, approx.
Mutual capacitance:
67 %
Rel. 50173, Acc