Poznámky redaktora
AWG-No.
weight
kg km
Outer Ø
app. km
Alu weight
kg km
Cop. kV
Ⴠ Longitudinally water-tight wrapping round conductor, multi-wire
Ⴠ Outer sheath PE
compound typeDMP2 620 S2
Ⴠ Further types and dimensions request.
2
780,0
102,0
182,0
26,0
16
3,4
6 10
12
rm 16
1 35
32600
1
850,0
145,0
182,0
28,0
16
3,4
6 10
12
rm 16
1 50
32601
2/0
980,0
203,0
182,0
30,0
16
3,4
6 10
12
rm 16
1 70
32602
3/0
1080,0
276,0
182,0
31,0
16
3,4
6 10
12
rm 16
1 95
32603
4/0
1150,0
348,0
182,0
32,0
16
3,4
6 10
12
rm 16
1 120
32604
300 kcmil
1280,0
435,0
283,0
34,0
25
3,4
6 10
12
rm 25
1 150
32605
350 kcmil
1420,0
537,0
283,0
36,0
25
3,4
6 10
12
rm 25
1 185
32606
500 kcmil
1630,0
696,0
283,0
38,0
25
3,4
6 10
12
rm 25
1 240
32607
600 kcmil
1950,0
870,0
283,0
40,0
25
3,4
6 10
12
rm 25
1 300
32608
750 kcmil
2350,0
1160,0
394,0
44,0
35
3,4
6 10
12
rm 35
1 400
32609
1000 kcmil
2780,0
1450,0
394,0
47,0
35
3,4
6 10
12
rm 35
1 500
32610
1
920,0
145,0
182,0
33,0
16
5,5
12 20
24
rm 16
1 50
32611
2/0
1030,0
203,0
182,0
34,0
16
5,5
12 20
24
rm 16
1 70
32612
3/0
1140,0
276,0
182,0
36,0
16
5,5
12 20
24
rm 16
1 95
32613
4/0
1250,0
348,0
182,0
37,0
16
5,5
12 20
24
rm 16
1 120
32614
300 kcmil
1320,0
435,0
283,0
39,0
25
5,5
12 20
24
rm 25
1 150
32615
350 kcmil
1570,0
537,0
283,0
41,0
25
5,5
12 20
24
rm 25
1 185
32616
500 kcmil
1780,0
696,0
283,0
43,0
25
5,5
12 20
24
rm 25
1 240
32617
600 kcmil
2100,0
870,0
283,0
45,0
25
5,5
12 20
24
rm 25
1 300
32618
750 kcmil
2480,0
1160,0
394,0
48,0
35
5,5
12 20
24
rm 35
1 400
32619
1000 kcmil
2900,0
1450,0
394,0
50,0
35
5,5
12 20
24
rm 35
1 500
32620
1250 kcmil
3380,0
1827,0
394,0
52,0
35
5,5
12 20
24
rm 35
1 630
33090
1500 kcmil
4400,0
2320,0
394,0
57,0
35
5,5
12 20
24
rm 35
1 800
33091
2000 kcmil
4780,0
2900,0
394,0
62,0
35
5,5
12 20
24
rm 35
1 1000
33097
Continuation Ⴇ
597
Energy- and Power Cable Medium Voltage Power Cables
Q
. This sheath not flame retardant
acc. The PE-outer sheath resistant high mechanical stress for laying the cables.
mm²
Insulation
thickness
mm
Nominal
voltage
kV
Operation
voltage
max.NA2XS(F)2Y 6/10kV, 12/20kV, 18/30kVXLPE-insulated,
alu-conductor, single core, longitudinally water-tight, screened, PE-sheath
Properties
Cable structure
Technical data
Ⴠ Aluminium-conductor, to
DIN VDE 0295 cl. mm
Screen
cross-sec. For this reason recommend
a peeling tool for installation. DIN 60332-1-2. +90°C Outer extrusion semi-conducting
coating spliced with the XLPE-insulation
Ⴠ Short circuit temperature
+250°C (short circuit duration max. kV
for 18/30 max.
The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer the XLPE insulation assures
a construction free partial discharges with high operational reliability.2
Ⴠ Ⴠ
XLPE-insulated power cables to
DIN VDE 0276 part 620, 620 S2
and IEC 60502
The materials used manufacture are
cadmium-free and contain silicone
and free from substances harmful to
the wetting properties lacquers
Ⴠ Ⴠ
Temperature range
during installation -20°C
Inner semi-conducting coating
Ⴠ Installation notes
To guarantee optimum operating
reliability the extruded semi-conductive
layer spliced with the insulation for long
duration.
mm²
Part no.
Weight
app.cores x
cross-sec. Longitudinally water-tight, conductive
wrapping
Ⴠ Nominal voltages
U0/U 6/10 kV, 12/20 kV, 18/30 kV
Note
Ⴠ Screen: Braiding copper wires with one
or two tapes applied helically
Ⴠ Operating voltages
for 6/10 max. The actual cross-section mm².
No.
Ⴠ Sheath colour black
Ⴠ Test voltages
for 6/10 kV
for 12/20 kV
for 18/30 kV
Ⴠ Sheath thickness voltage 2,5 mm
Ⴠ Minimum bending radius
15x cable Ø
Ⴠ Power ratings
see Technical Informations
Application
Suitable for indoor installation and cable ducts, outdoors, underground and water well for installation cable trays for industries,
switch-boards and power stations.2, IEC 60228 cl.2, multi-wire,
BS 6360 cl.
Ⴠ AWG sizes are approximate equivalent
values.
Ⴠ Core insulation cross-linked polyethylene
(XLPE), compound type DIX8 620 S2
Ⴠ Operating temperature
max. kV
for 12/20 max