HELUKABEL: Katalog kabelů a vodičů 2018 (EN)

| Kategorie: Katalog  |

Vydal: Helukabel CZ s.r.o.

Strana 597 z 1153

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.

Jak získat tento dokument?






Poznámky redaktora
The PE-outer sheath resistant high mechanical stress for laying the cables. Ⴠ Core insulation cross-linked polyethylene (XLPE), compound type DIX8 620 S2 Ⴠ Operating temperature max. For this reason recommend a peeling tool for installation. DIN 60332-1-2. Ⴠ Test voltages for 6/10 kV for 12/20 kV for 18/30 kV Ⴠ Minimum bending radius 15x cable Ø Ⴠ Power ratings see Technical Informations Application Suitable for indoor installation and cable ducts, outdoors, underground and water well for installation cable trays for industries, switch-boards and power stations. kV for 12/20 max. km Aluweight kg km Cop.2 Ⴠ Ⴠ XLPE-insulated power cables to DIN VDE 0276 part 620, 620 and IEC 60502 The materials used manufacture are cadmium-free and contain silicone and free from substances harmful to the wetting properties lacquers Ⴠ Ⴠ Temperature range during installation -20°C Inner semi-conducting coating Ⴠ Installation notes To guarantee optimum operating reliability the extruded semi-conductive layer spliced with the insulation for long duration. weight kg km Outer Ø min. Wrapping conductive material Ⴠ Nominal voltages U0/U 6/10 kV, 12/20 kV, 18/30 kV Ⴠ Screen: Braiding copper wires with one or two tapes applied helically Note Ⴠ Ⴠ Wrapping Operating voltages for 6/10 max. +90°C Outer extrusion semi-conducting coating spliced with the insulation Ⴠ Short circuit temperature +250°C (short circuit duration max. kV for 18/30 max. The actual cross-section mm². Weight app. 1 710,0 145,0 182,0 24,0 29,0 2,5 3,4 6 10 12 rm 16 1 50 32520 2/0 790,0 203,0 182,0 26,0 31,0 2,5 3,4 6 10 12 rm 16 1 70 32521 3/0 920,0 276,0 182,0 26,0 32,0 2,5 3,4 6 10 12 rm 16 1 95 32522 4/0 990,0 348,0 182,0 28,0 34,0 2,5 3,4 6 10 12 rm 16 1 120 32523 300 kcmil 1110,0 435,0 182,0 29,0 35,0 2,5 3,4 6 10 12 rm 16 1 150 32524 300 kcmil 1220,0 435,0 283,0 29,0 35,0 2,5 3,4 6 10 12 rm 25 1 150 32525 350 kcmil 1260,0 537,0 182,0 31,0 37,0 2,5 3,4 6 10 12 rm 16 1 185 32526 350 kcmil 1370,0 537,0 283,0 33,0 39,0 2,5 3,4 6 10 12 rm 25 1 185 32527 500 kcmil 1480,0 696,0 182,0 33,0 39,0 2,5 3,4 6 10 12 rm 16 1 240 32528 500 kcmil 1530,0 696,0 283,0 33,0 39,0 2,5 3,4 6 10 12 rm 25 1 240 32529 600 kcmil 1820,0 870,0 283,0 36,0 41,0 2,5 3,4 6 10 12 rm 25 1 300 32530 750 kcmil 2220,0 1160,0 394,0 40,0 45,0 2,5 3,4 6 10 12 rm 35 1 400 32531 1000 kcmil 2570,0 1450,0 394,0 43,0 48,0 2,5 3,4 6 10 12 rm 35 1 500 32532 1 890,0 145,0 182,0 28,0 33,0 2,5 5,5 12 20 24 rm 16 1 50 32533 2/0 970,0 203,0 182,0 30,0 35,0 2,5 5,5 12 20 24 rm 16 1 70 32534 3/0 1120,0 276,0 182,0 31,0 36,0 2,5 5,5 12 20 24 rm 16 1 95 32535 4/0 1210,0 348,0 182,0 32,0 38,0 2,5 5,5 12 20 24 rm 16 1 120 32536 300 kcmil 1370,0 435,0 182,0 33,0 39,0 2,5 5,5 12 20 24 rm 16 1 150 32537 300 kcmil 1420,0 435,0 283,0 33,0 39,0 2,5 5,5 12 20 24 rm 25 1 150 32538 350 kcmil 1530,0 537,0 182,0 35,0 41,0 2,5 5,5 12 20 24 rm 16 1 185 32539 350 kcmil 1570,0 537,0 283,0 35,0 41,0 2,5 5,5 12 20 24 rm 25 1 185 32540 500 kcmil 1720,0 696,0 182,0 38,0 44,0 2,5 5,5 12 20 24 rm 16 1 240 32541 500 kcmil 1830,0 696,0 283,0 38,0 44,0 2,5 5,5 12 20 24 rm 25 1 240 32542 600 kcmil 2070,0 870,0 283,0 40,0 46,0 2,5 5,5 12 20 24 rm 25 1 300 32543 750 kcmil 2460,0 1160,0 394,0 43,0 49,0 2,5 5,5 12 20 24 rm 35 1 400 32544 1000 kcmil 2890,0 1450,0 394,0 46,0 52,0 2,5 5,5 12 20 24 rm 35 1 500 32545 1250 kcmil 3370,0 1827,0 394,0 47,0 53,0 2,5 5,5 12 20 24 rm 35 1 630 33078 1 1120,0 145,0 182,0 32,0 38,0 2,5 8 18 30 36 rm 16 1 50 32546 Continuation Ⴇ 595 Energy- and Power Cable Medium Voltage Power Cables Q . max.cores x cross-sec. mm Sheath thickness Nominal value mm Insulation thickness mm Nominal voltage kV Operation voltage max.NA2XS2Y 6/10kV, 12/20kV, 18/30kV XLPE-insulated, Alu-conductor, single core, screened, PE-sheath Properties Cable structure Technical data Ⴠ Aluminium-conductor, to DIN VDE 0295 cl.2, multi-wire, BS 6360 cl. This sheath not flame retardant acc. The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer the XLPE insulation assures a construction free partial discharges with high operational reliability. No. AWG-No. mm² Part no.2, IEC 60228 cl. Ⴠ Sheath colour black AWG sizes are approximate equivalent values. kV Ⴠ Outer sheath PE compound type DMP2 620 S2 Ⴠ round conductor, multi-wire Ⴠ Further dimensions available request