Poznámky redaktora
kV
for 12/20 max.2, IEC 60228 cl. km
Cop. kV
Ⴠ Longitudinally water-tight wrapping round conductor, multi-wire
Ⴠ Aluminium tape spliced with
PE sheath
Ⴠ Further types and dimensions request.
Weight
app.
mm²
Part no.
No.cores x
cross-sec.
mm²
Insulation
thickness
mm
Nominal
voltage
kV
Operation
voltage
max. The PE
sheathing not flame-retardant DIN 60332-1-2. The resistant Al/PE-laminated sheathing acts cross water barrier.
2
860,0
518,0
28,0
2,5
16
3,4
6 10
12
rm 16
1 35
33054
1
1000,0
662,0
30,0
2,5
16
3,4
6 10
12
rm 16
1 50
33055
2/0
1350,0
854,0
32,0
2,5
16
3,4
6 10
12
rm 16
1 70
33056
3/0
1680,0
1094,0
33,0
2,5
16
3,4
6 10
12
rm 16
1 95
33057
4/0
2070,0
1334,0
34,0
2,5
16
3,4
6 10
12
rm 16
1 120
33058
300 kcmil
2350,0
1723,0
36,0
2,5
25
3,4
6 10
12
rm 25
1 150
33059
350 kcmil
2710,0
2059,0
38,0
2,5
25
3,4
6 10
12
rm 25
1 185
33060
500 kcmil
3260,0
2587,0
40,0
2,5
25
3,4
6 10
12
rm 25
1 240
33061
600 kcmil
3850,0
3163,0
42,0
2,5
25
3,4
6 10
12
rm 25
1 300
38049
750 kcmil
4740,0
4234,0
46,0
2,5
35
3,4
6 10
12
rm 35
1 400
38050
1000 kcmil
5800,0
5194,0
49,0
2,5
35
3,4
6 10
12
rm 35
1 500
38051
1250 kcmil
7120,0
6442,0
51,0
2,5
35
3,4
6 10
12
rm 35
1 630
38052
2
1020,0
518,0
33,0
2,5
16
5,5
12 20
24
rm 16
1 35
38053
1
1170,0
662,0
35,0
2,5
16
5,5
12 20
24
rm 16
1 50
33066
2/0
1470,0
854,0
36,0
2,5
16
5,5
12 20
24
rm 16
1 70
33067
3/0
1860,0
1094,0
38,0
2,5
16
5,5
12 20
24
rm 16
1 95
33083
4/0
2260,0
1334,0
39,0
2,5
16
5,5
12 20
24
rm 16
1 120
33069
300 kcmil
2550,0
1723,0
41,0
2,5
25
5,5
12 20
24
rm 25
1 150
33070
350 kcmil
2920,0
2059,0
43,0
2,5
25
5,5
12 20
24
rm 25
1 185
33071
500 kcmil
3490,0
2587,0
45,0
2,5
25
5,5
12 20
24
rm 25
1 240
33072
600 kcmil
4090,0
3163,0
47,0
2,5
25
5,5
12 20
24
rm 25
1 300
33073
750 kcmil
5010,0
4234,0
50,0
2,5
35
5,5
12 20
24
rm 35
1 400
33074
1000 kcmil
6090,0
5194,0
54,0
2,5
35
5,5
12 20
24
rm 35
1 500
33075
1250 kcmil
7440,0
6442,0
55,0
2,5
35
5,5
12 20
24
rm 35
1 630
38054
Continuation Ⴇ
591
Energy- and Power Cable Medium Voltage Power Cables
Q
.N2XS(FL)2Y 6/10kV, 12/20kV, 18/30kVXLPE-insulated,
Cu-conductor, single core, longitudinally and crosswise water-tight, screened, PE-sheath
Properties
Cable structure
Technical data
Ⴠ Bare copper-conductor, to
DIN VDE 0295 cl. The cable can severely mechanically stressed during installation and operation. inhibits the diffusion water.
Ⴠ Outer sheath PE
compound type DMP2 620 S2
Ⴠ Test voltages
for 6/10 kV
for 12/20 kV
for 18/30 kV
Ⴠ Sheath colour black
Ⴠ Minimum bending radius
15x cable Ø
Ⴠ Power ratings
see Technical Informations
Application
Installation primarily for power utility grids and cable ducts, outdoors, underground and water, and also pallets for manufacturing plants,
switchgear and power stations.
Ⴠ AWG sizes are approximate equivalent
values.
AWG-No. kV
for 18/30 max.2, multi-wire,
BS 6360 cl. +90°C Outer extrusion semi-conducting
coating spliced with the XLPE-insulation
Ⴠ Short circuit temperature
+250°C (short circuit duration max. case of
sheathing damage, water impact contained the flaw. The internal conductive layer between conductor and VPE insulation and the adherent external
conductive layer the VPE insulation guarantees design with high operational safety and partial discharge. For this reason recommend
a peeling tool for installation
Ⴠ Core insulation cross-linked polyethylene
(XLPE), compound type DIX8 620 S2
Ⴠ Operating temperature
max. Longitudinally water-tight, conductive
wrapping
Ⴠ Nominal voltages
U0/U 6/10 kV, 12/20 kV, 18/30 kV
Note
Ⴠ Screen: Braiding copper wires with
one two tapes applied helically
Ⴠ Operating voltages
for 6/10 max. mm
Sheath
thickness
Nominal
value
mm
Screen
cross-sec. The actual cross-section mm².
weight
kg km
Outer Ø
app.2
Ⴠ Ⴠ
XLPE-insulated power cables to
DIN VDE 0276 part 620, 620 S2
and IEC 60502
The materials used manufacture are
cadmium-free and contain silicone
and free from substances harmful to
the wetting properties lacquers
Ⴠ Ⴠ
Temperature range
during installation -20°C
Inner semi-conducting coating
Ⴠ Installation notes
To guarantee optimum operating
reliability the extruded semi-conductive
layer spliced with the insulation for long
duration