Poznámky redaktora
kV
for 18/30 max.N2XSY 6/10kV, 12/20kV, 18/30kVXLPE-insulated,
Cu-conductor, single core, screened, PVC-sheath
Properties
Cable structure
Technical data
Ⴠ Bare copper-conductor, to
DIN VDE 0295 cl.
2
905,0
518,0
23,0 28,0
2,5
3,4
6 10
12
rm 16
1 35
32400
1
1080,0
662,0
24,0 29,0
2,5
3,4
6 10
12
rm 16
1 50
32401
2/0
1310,0
854,0
26,0 31,0
2,5
3,4
6 10
12
rm 16
1 70
32402
3/0
1580,0
1094,0
26,0 32,0
2,5
3,4
6 10
12
rm 16
1 95
32403
4/0
1860,0
1334,0
28,0 34,0
2,5
3,4
6 10
12
rm 16
1 120
32404
300 kcmil
2040,0
1622,0
29,0 35,0
2,5
3,4
6 10
12
rm 16
1 150
32405
300 kcmil
2210,0
1723,0
29,0 35,0
2,5
3,4
6 10
12
rm 25
1 150
32406
350 kcmil
2450,0
1958,0
31,0 37,0
2,5
3,4
6 10
12
rm 16
1 185
32407
350 kcmil
2580,0
2059,0
31,0 37,0
2,5
3,4
6 10
12
rm 25
1 185
32408
500 kcmil
3000,0
2486,0
33,0 39,0
2,5
3,4
6 10
12
rm 16
1 240
32409
500 kcmil
3130,0
2587,0
33,0 39,0
2,5
3,4
6 10
12
rm 25
1 240
32410
600 kcmil
3780,0
3163,0
36,0 41,0
2,5
3,4
6 10
12
rm 25
1 300
32411
750 kcmil
4670,0
4234,0
40,0 45,0
2,5
3,4
6 10
12
rm 35
1 400
32412
1000 kcmil
5750,0
5194,0
43,0 48,0
2,5
3,4
6 10
12
rm 35
1 500
32413
1250 kcmil
7180,0
6442,0
44,0 49,0
2,5
3,4
6 10
12
rm 35
1 630
33099
2
1110,0
518,0
27,0 32,0
2,5
5,5
12 20
24
rm 16
1 35
32414
1
1250,0
662,0
28,0 33,0
2,5
5,5
12 20
24
rm 16
1 50
32415
2/0
1510,0
854,0
30,0 35,0
2,5
5,5
12 20
24
rm 16
1 70
32416
3/0
1780,0
1094,0
31,0 36,0
2,5
5,5
12 20
24
rm 16
1 95
32417
4/0
2070,0
1334,0
32,0 38,0
2,5
5,5
12 20
24
rm 16
1 120
32418
300 kcmil
2310,0
1622,0
33,0 39,0
2,5
5,5
12 20
24
rm 16
1 150
32419
300 kcmil
2420,0
1723,0
33,0 39,0
2,5
5,5
12 20
24
rm 25
1 150
32420
350 kcmil
2650,0
1958,0
35,0 41,0
2,5
5,5
12 20
24
rm 16
1 185
32421
350 kcmil
2810,0
2059,0
35,0 41,0
2,5
5,5
12 20
24
rm 25
1 185
32422
500 kcmil
3260,0
2486,0
38,0 44,0
2,5
5,5
12 20
24
rm 16
1 240
32423
500 kcmil
3360,0
2587,0
38,0 44,0
2,5
5,5
12 20
24
rm 25
1 240
32424
600 kcmil
4020,0
3163,0
40,0 46,0
2,5
5,5
12 20
24
rm 25
1 300
32425
750 kcmil
4930,0
4234,0
43,0 49,0
2,5
5,5
12 20
24
rm 35
1 400
32426
1000 kcmil
6050,0
5194,0
46,0 52,0
2,5
5,5
12 20
24
rm 35
1 500
32427
1250 kcmil
7510,0
6442,0
47,0 53,0
2,5
5,5
12 20
24
rm 35
1 630
33096
Continuation Ⴇ
585
Energy- and Power Cable Medium Voltage Power Cables
Q
. kV
Ⴠ Outer sheath PVC
compound type DMV6 620 S2
Ⴠ Sheath colour red
Ⴠ Test voltages
for 6/10 kV
for 12/20 kV
for 18/30 kV
Note
Ⴠ round conductor, multi-wire
Ⴠ Further dimensions available request.
No.cores x
cross-sec. The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer
on the XLPE insulation assures construction free partial discharges with high operational reliability. +90°C Outer conductive layer extruded and
welded with core insulation
Ⴠ Short circuit temperature
+250°C (short circuit duration max. Due the good laying characteristic, this can also laid easily
in difficult line guideways.
AWG-No.2, IEC 60228 cl.
mm²
Part no.2, multi-wire,
BS 6360 cl.
Ⴠ Minimum bending radius
15x cable Ø
Ⴠ AWG sizes are approximate equivalent
values.2
Ⴠ Ⴠ
XLPE-insulated power cables to
DIN VDE 0276 part 620, 620 S2
and IEC 60502
The materials used manufacture are
cadmium-free and contain silicone
and free from substances harmful to
the wetting properties lacquers
Ⴠ Ⴠ
Temperature range
during installation -5°C
Inner semi-conducting coating
Tests
Ⴠ Core insulation cross-linked polyethylene
(XLPE), compound type DIX8 620 self-extinguishing and flame retardant
acc.
mm
Sheath
thickness
Nominal
value
mm
Insulation
thickness
mm
Nominal
voltage
kV
Operation
voltage
max. km
Cop.
Ⴠ Wrapping
Ⴠ Operating voltages
for 6/10 max. Conductive taping
Installation notes
Ⴠ Nominal voltages
U0/U 6/10 kV, 12/20 kV, 18/30 kV
Ⴠ Screen: Braiding copper wires with one
or two tape(s) applied helically guarantee optimum operating
reliability the extruded semi-conductive
layer spliced with the insulation for long
duration.
weight
kg km
Outer Ø
min.
Ⴠ Power ratings table
see Technical Informations
Application
Suitable for installation mostly for power supply stations, indoors and cable ducts,outdoor with protected laying, underground and water as
well for installation cable trays for industries, switch-boards and power stations. For this reason recommend
a peeling tool for installation. DIN VDE 0482-332-1-2,
DIN 60332-1-2, IEC 60332-1 (equivalent
DIN VDE 0472 part 804 test method B)
Ⴠ Operating temperature
max. max. kV
for 12/20 max. The actual cross-section mm².
Weight
app