HELUKABEL: Katalog kabelů a vodičů 2018 (EN)

| Kategorie: Katalog  |

Vydal: Helukabel CZ s.r.o.

Strana 573 z 1153

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.

Jak získat tento dokument?






Poznámky redaktora
DIN VDE 0482 part 267, DIN 50267-2-2, IEC 60754-2 (equivalent DIN VDE 0472 part 813) Ⴠ Halogen-free acc. These cables are suitable for outdoor applications and underground using conduits tubes. = The product conformed with the Low-Voltage Directive 2006/95/EC. DIN VDE 0482 part 267, DIN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815) Ⴠ Smoke density acc. Caloric load values see Technical Informations Ⴠ Sheath colour orange Tests Ⴠ Flame test acc. The actual cross-section mm². AWG-No. mm No.2, single-wire or multi-wire, 6360 cl. Suitable for fixed installation in dry and moist rooms, in, above, and beneath plaster well masonary walls and concrete. DIN VDE 0482 part 1034-1+2, DIN 61034-1+2, IEC 61034-1+2, 7622 part 1+2 (previously DIN VDE 0472 part 816) Note Ⴠ round conductor, single-wire rm round conductor, multi-wire Ⴠ AWG sizes are approximate equivalent values. This fulfils the demands technical guide lines for fire protection (supplement DIN VDE 0108 part 1).1 cl.1 cl. Ⴠ Corrosiveness combustion gases acc. km Cop.cores x cross-sec. mm No. Tests acc. For the installation conduit all precautions must taken that accumulation water can occur in the pipes.cores x cross-sec. 6 250,0 154,0 11,5 1 rm 52534 2/0 840,0 672,0 17,5 1 rm 52538 3/0 1120,0 912,0 19,5 1 rm 52539 4 360,0 240,0 13,0 1 rm 52535 2 460,0 336,0 14,0 1 rm 52536 4/0 1390,0 1152,0 21,5 1 120 rm 52540 300 kcmil 1690,0 1440,0 23,5 1 150 rm 52541 1 610,0 480,0 15,5 1 rm 52537 Continuation Ⴇ 571 Energy- and Power Cable Low Voltage and Security Cables Q .to DIN VDE 0472 part 814 IEC 60331.1 cl. mm² Part no.N2XH-FE 180/E 90security cable, halogen-free, 0,6/1 kV, with improved fire characteristics Properties Cable structure Technical data Ⴠ Bare copper-conductor, to DIN VDE 0295 cl.2 Ⴠ Ⴠ Halogen-free security cable with improved characteristics the case fire to DIN VDE 0266 Halogen-free; evolution corrosive and toxic gases Ⴠ Flame retardant and hardly flammable Ⴠ Temperature range -30°C +70°C Ⴠ Self-extinguished and fire resistant Ⴠ Core insulation with cross-linked polyethylene, compound type 2XI1 to DIN VDE 0276 part 604 Ⴠ flame propagation, therefore security from fire Ⴠ Permissible operating temperature at conductor +90°C Low smoke density, darkening of emergency exits without hindering the fire extinguishing works Ⴠ Core identification DIN VDE 0293-308 and 0276 part 604 Ⴠ Nominal voltage U0/U 0,6/1 kV Ⴠ Test voltage 4000 V Ⴠ GN-YE conductor, cores and above Toxicological harmless Ⴠ Minimum bending radius 12x cable Cores stranded layers self-ignition Ⴠ Overall core covering, halogen-free filling compound, pressed Ⴠ Radiation resistance up 200x106 cJ/kg (up 200 Mrad) Ⴠ Maintenance functionality during the increased current load Ⴠ Outer sheath thermoplastic halogen-free polyolefine, flame retardant Ⴠ Ⴠ 180: Insulation integrity for 180 minutes. Test method DIN 4102 part 12. AWG-No. weight kg km Outer Ø app. Weight app. mm² Part no. Ⴠ LSOH Low Smoke Zero Halogen Application Everywhere, where case fire human life and material assets are protected and safety conciousness take special significance, in industrial complexes, power stations, communal establishment, hotels, airports, underground railway networks, hospitals and outpatients clinic (DIN VDE 0107), department stores, data processing centres, theaters, cinemas, multi-storey buildings, public gatherings, schools etc. to DIN VDE 0482-332-3, 4066 part 3, DIN 60332-3, IEC 60332-3 (previously DIN VDE 0472 part 804 test method C) Ⴠ 90: Functionality electrical cable systems for minimum minutes. weight kg km Outer Ø app. Weight app. (DIN VDE 0108), mining works, offshore plants, leading centres, traffic communication, emergency power supply and alarm systems. Insulation integrity under direct flame propagation for the test period of 180 minutes. km Cop.2, IEC 60228 cl. The functionality for minutes assures the functional performance of water-pressure-rising stations for the supply avoid smoke and heat in safety-stairs and inner rooms, ladder shafts and engine rooms for fire brigade lifts, emergency lifts for sickbeds hospitals and the fire brigade lifts