Poznámky redaktora
2,
IEC 60228 cl.
mm²
Part no. DIN VDE 0482-332-3-24,
BS 4066 part DIN 60332-3-24,
IEC 60332-3-24 (previously DIN VDE 0472
part 804 test method C)
Ⴠ Overall filled inner sheat
Ⴠ Minimum bending radius
12x cable Covered filling compound taping
Ⴠ Concentric conductor bare Cu-wires
Ⴠ Radiation resistance
up 100x106 cJ/kg (up 100 Mrad) Corrosiveness combustion gases
acc.
weight
kg km
Outer Ø
app.
mm²
Part no. These cables are suitable for outdoor applications and underground using
in conduits tubes.1 cl. For the installation conduit all precautions must taken that accumulation water can occur the pipes
= The product conformed with the Low-Voltage Directive 2006/95/EC.
Weight
app.1 cl.
weight
kg km
Outer Ø
app.2
Ⴠ Ⴠ
Power and control cable acc. mm
No. DIN VDE 0482
part 1034-1+2, DIN 61034-1+2,
IEC 61034-1+2, 7622 part 1+2
(previously DIN VDE 0472 part 816)
Note
Ⴠ round conductor, single-wire
rm round conductor, multi-wire
sm sectional conductor, multi-wire
Ⴠ AWG sizes are approximate equivalent
values.
The concentric conductor can used PEN conductor screen. DIN VDE 0482 part 267,
DIN 50267-2-2, IEC 60754-2
(equivalent DIN VDE 0472 part 813)
Ⴠ Outer sheath thermoplastic
polyolefine, compound type HM4
to 604 S1
Ⴠ Caloric load values
see Technical Informations
Ⴠ Sheath colour black
Ⴠ Halogen-free acc. The actual cross-section mm².
16
250,0
53,0
12,0
2 1,5 1,5 re
53200 12
480,0
202,0
17,5
4 re
53223
10
600,0
297,0
19,0
4 re
53224
14
280,0
81,0
13,0
2 2,5 2,5 re
53201
12
320,0
122,0
14,0
2 re
53202 8
850,0
504,0
21,5
4 re
53225
6
1200,0
797,0
24,5
4 re
53226
10
400,0
183,0
15,0
2 re
53203
8
560,0
311,0
16,0
2 re
53204 4
1800,0
1142,0
29,0
4 rm
53227
2
2100,0
1528,0
29,5
4 rm
53228
6
780,0
490,0
19,1
2 re
53205
1
2800,0
2203,0
32,5
4 sm
53229
16
250,0
67,0
13,0
3 1,5 1,5 re
53206
2/0
3800,0
3082,0
38,0
4 sm
53230
14
320,0
104,0
14,0
3 2,5 2,5 re
53207
3/0
5100,0
4208,0
43,5
4 sm
53231
12
400,0
161,0
16,5
3 re
53208
4/0
6556,0
5388,0
50,5
4 120 sm
53758
10
500,0
242,0
18,0
3 re
53209
300 kcmil
7600,0
6540,0
52,1
4 150 sm
53759
8
750,0
408,0
20,0
3 re
53210
350 kcmil
9370,0
8159,0
57,2
4 185 sm
53760
6
1000,0
643,0
22,5
3 re
53211
500 kcmil
11611,0
10546,0
62,6
4 240 120 sm
53761
4
1600,0
902,0
27,0
3 rm
53212
16
320,0
132,0
15,0
7 1,5 2,5 re
53232
2
1900,0
1190,0
27,5
3 rm
53213
1
2400,0
1723,0
32,3
3 rm
53214 14
400,0
200,0
15,5
7 2,5 2,5 re
53239
12
580,0
316,0
18,1
7 re
53246
2/0
3060,0
2410,0
35,6
3 sm
53215
3/0
4200,0
3296,0
39,0
3 sm
53216 16
420,0
177,0
17,2
10 1,5 2,5 re
53233
4/0
5207,0
4236,0
42,0
3 120 sm
53217 14
550,0
287,0
18,9
10 2,5 re
53240
300 kcmil
5700,0
5100,0
43,5
3 150 sm
53218 16
460,0
204,0
18,4
12 1,5 2,5 re
53234
350 kcmil
7150,0
6383,0
47,4
3 185 sm
53219 14
610,0
335,0
19,2
12 2,5 re
53241
500 kcmil
9250,0
8240,0
53,5
3 240 120 sm
53220 12
910,0
528,0
22,6
12 re
53247
16
300,0
81,0
13,5
4 1,5 1,5 re
53221 16
686,0
275,0
20,0
16 1,5 re
53235
14
380,0
129,0
14,5
4 2,5 2,5 re
53222 14
805,0
450,0
20,9
16 2,5 re
53242
Continuation Ⴇ
559
Energy- and Power Cable Low Voltage and Security Cables
Q
.
AWG-No. km
Cop. AWG-No.
to DIN VDE 0276 part 604,
HD 604 part and part 5G
Halogen-free, liberation of
corrosive toxic gases
Ⴠ Limited propagation fire
Ⴠ Temperature range
during installation -5°C +50°C
fixed installation -30°C +90°C
Ⴠ Low smoke development
Ⴠ Core insulation cross-linked
polyethylene (XLPE)
compound type 2XI1 604 S1
Ⴠ The materials used manufacture are
cadmium-free and contain silicone
and free from substances harmful to
the wetting properties lacquers
Ⴠ Permissible operating temperature
at conductor +90°C Core identification DIN VDE 0293-308
Ⴠ Cores stranded layers
(for multi-core cables)
Ⴠ Nominal voltage U0/U 0,6/1 Tests
Ⴠ Test voltage Flame test acc.cores x
cross-sec.N2XCHpower cable, 0,6/1kV, halogen-free, with concentric conductor, without
functionality
Properties
Cable structure
Technical data
Ⴠ Bare copper-conductor, to
DIN VDE 0295 cl. DIN VDE 0482
part 267, DIN 50267-2-1, IEC 60754-1
(equivalent DIN VDE 0472 part 815)
Ⴠ Smoke density acc. km
Cop.
Weight
app.2, single-wire
or multi-wire, 6360 cl. mm
No.cores x
cross-sec.1 cl.
Ⴠ LS0H Low Smoke Zero Halogen
Application
The power cables with enhanced characteristics case fire are used power stations. Suitable for fixed installation dry, damp wet environments, in, above,
on and beneath plaster well masonary walls and concrete