Strana 553 z 1153
Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.
Poznámky redaktora
AWG-No.1 cl.
mm²
-
6
33125
-
6
33113
98,0
47,0
11,5
re
1 16
-
4
33126
-
4
33114
150,0
73,0
12,5
re
1 25
-
2
33127
-
2
33115
241,0
102,0
13,5
re
1 35
-
1
33128
-
1
33116
357,0
145,0
15,5
rm
1 50
-
2/0
33129
-
2/0
33117
409,0
203,0
17,0
rm
1 70
-
3/0
33130
-
3/0
33118
570,0
276,0
19,0
rm
1 95
-
4/0
33131
-
4/0
33119
590,0
348,0
20,5
rm
1 120
-
300 kcmil
33132
-
300 kcmil
33120
804,0
435,0
23,0
rm
1 150
-
350 kcmil
33133
-
350 kcmil
33121
978,0
537,0
25,5
rm
1 185
-
500 kcmil
33134
-
500 kcmil
33122
1253,0
696,0
28,5
rm
1 240
-
600 kcmil
33135
-
600 kcmil
33123
1394,0
870,0
30,0
rm
1 300
-
750 kcmil
33136
-
750 kcmil
33124
1890,0
1160,0
34,0
rm
1 400
-
6
33147
-
6
33137
750,0
186,0
21,5
re
4 16
-
4
33148
-
4
33138
950,0
290,0
26,0
re
4 25
-
2
33149
-
2
33139
1120,0
406,0
27,5
re
4 35
-
1
33150
-
1
33140
1251,0
580,0
30,0
se
4 50
-
2/0
33151
-
2/0
33141
1548,0
812,0
34,0
se
4 70
-
3/0
33152
-
3/0
33142
2030,0
1102,0
39,0
se
4 95
-
4/0
33153
-
4/0
33143
2400,0
1392,0
42,5
se
4 120
-
300 kcmil
33154
-
300 kcmil
33144
3030,0
1740,0
47,5
se
4 150
-
350 kcmil
33155
-
350 kcmil
33145
3650,0
2146,0
52,0
se
4 185
-
500 kcmil
33156
-
500 kcmil
33146
4800,0
2784,0
58,0
se
4 240
Dimensions and specifications may changed without prior notice. Respecting the permissible operating temperature the
conductor +90°C permits higher current carrying capacity than PVC insulated power distribution cables. DIN VDE 0482-332-1-2,
DIN 60332-1-2, IEC 60332-1 (equivalent
DIN VDE 0472 part 804 test method B)
Ⴠ Permissible operating temperature
at conductor +90°C Core identification to
DIN VDE 0293-308, 0276 part 603
Ⴠ Permissible short circuit temperature
(short circuit duration max.
O type
Part no. permissible tensile stress
with cable grip conductor
30 N/mm²
Ⴠ Three-phase systems 1,2 kV
Ⴠ Minimum bending radius
single-core 15x cable Ø
multi-core 12x cable Note
Ⴠ round conductor, single-wire
rm round conductor, multi-wire
se sectional conductor, single-wire
Ⴠ J-version with GN-YE conductor
O-version without GN-YE conductor
Ⴠ AWG sizes are approximate equivalent
values.
Application
Power distribution cables for use underground, water, outdoors, concrete, indoors, cable ducts, for power stations, industrial applications
and switching systems, well local networks mechanical damage expected. mm
No.2, IEC 60228
cl.
Weight
app.1 cl.
= The product conformed with the Low-Voltage Directive 2006/95/EC.NA2XYpower cable, 0,6/1kV, VDE approved, higher current carrying capacity
Properties
Cable structure
Technical data
Ⴠ Aluminium-conductor DIN VDE 0295
cl.
J type
Part no. km
Alu weight
kg km
Outer Ø
app.
AWG-No. (RQ02)
551
Energy- and Power Cable Power Cables Power cables for energy supply
Q
. s)
+250°C
Ⴠ Cores stranded concentric layers Highest permissible voltage
Ⴠ
Ⴠ Direct current systems 1,8 kV
Outer sheath PVC
compound type DMV6/DMP2
to 603 S1
Ⴠ Nominal voltage U0/U 0,6/1 Alternating current systems
• Single-phase systems
both outer conductors insulated 1,4 kV
• Single-phase systems
one outer conductor earthed 0,7 kV
Ⴠ Test voltage kV
Ⴠ Sheath colour black
Ⴠ Max.2
Ⴠ Ⴠ
Power and control cable to
DIN VDE 0276 Part 603,
HD 603 and IEC 60502
The materials used manufacture are
cadmium-free and contain silicone
and free from substances harmful to
the wetting properties lacquers
Ⴠ Temperature range
flexing -5°C +50°C
fixed installation -40°C +70°C
Tests
Ⴠ Core insulation cross-linked
polyethylene (XLPE)
compound type DIX3 603 S1
Ⴠ self-extinguishing and flame retardant
acc.2, single-wire multi-wire,
BS 6360 cl.cores x
cross-sec.1 cl. The actual cross-section mm²