HELUKABEL: Katalog kabelů a vodičů 2018 (EN)

| Kategorie: Katalog  |

Vydal: Helukabel CZ s.r.o.

Strana 415 z 1153

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.

Jak získat tento dokument?






Poznámky redaktora
182 Ⴠ Sheath colour black (international colour code) grey (DIN 47100 preferred type from stock) Application As flexible interconnecting cable for electronics, control and command technology, well measurement, signal, and pulse technology. weight kg km Outer Ø app.50. 1581 tab.183 Ⴠ Minimum bending radius fixed 7,5x cable Ø flexing 15x cable Ø Note Ⴠ Colour coded DIN 47100 international colour code Ⴠ Coupling resistance max. = The product conformed with the Low-Voltage Directive 2006/95/EC. Sheath colour grey Weight app.1581 tab. mm AWG-No. UL-Style 1061/1729 for AWG 26-20, UL-Style 1007/1569 for AWG 18-16 The materials used manufacture are cadmium-free and contain silicone and free from substances harmful to the wetting properties lacquers Tests Ⴠ Temperature range flexing -10°C +80°C fixed installation -20°C +80°C Ⴠ PVC flame retardant acc. The actual cross-section mm². No. No. to UL-Std. to UL-Std. 250 Ohm/km AWG sizes are approximate equivalent values. Sheath colour black Part no. 85% coverage Ⴠ Outer sheath PVC class acc. ASTM-B 286 conductor make-up to 0,14 mm² 7x0,162 mm 0,23 mm² 7x0,202 mm 0,34 mm² 7x0,254 mm 0,56 mm² 7x0,32 mm 0,82 mm² 19x0,235 mm 1,30 mm² 19x0,31 mm Ⴠ Ⴠ Special PVC command cable, approved to UL-Style 2464, cores acc. Sheath colour grey 20,0 12,6 3,9 26 2 0,14 83976 83254 20,0 16,1 4,3 24 2 0,23 83987 83270 25,0 18,9 4,5 24 3 0,23 83988 83271 25,0 13,7 4,2 26 3 0,14 83977 83255 28,0 14,9 4,4 26 4 0,14 83978 83256 30,0 23,0 4,8 24 4 0,23 83989 83272 40,0 32,8 5,4 24 6 0,23 83990 83273 30,0 18,9 5,0 26 6 0,14 83979 83257 50,0 29,5 6,1 26 10 0,14 83980 83258 60,0 50,9 6,5 24 10 0,23 83991 83274 70,0 59,1 6,7 24 12 0,23 83992 83275 53,0 31,4 6,3 26 12 0,14 83981 83259 60,0 43,9 6,8 26 16 0,14 83982 83260 90,0 68,4 7,4 24 16 0,23 83993 83276 123,0 79,5 7,7 24 18 0,23 83994 83277 70,0 52,1 7,1 26 18 0,14 83983 83261 100,0 62,8 8,0 26 24 0,14 83984 83262 131,0 97,3 8,8 24 24 0,23 83995 83278 160,0 122,0 9,0 24 27 0,23 83996 83279 105,0 66,3 8,4 26 27 0,14 83985 83263 110,0 70,4 8,6 26 30 0,14 83986 83264 170,0 132,0 9,3 24 30 0,23 83997 83280 Continuation Ⴇ Cables according international Approvals Data Cables UL/CSA 413 N . Fast and inexpensive contacting cutting and clamping technology. kg km Cop. EMC Electromagnetic compatibillity To optimize the EMC features recommend large round contact the copper braiding both ends.cores x cross-sec. kg km Cop. Sheath colour black Part no. to UL VW-1, CSA FT1 Ⴠ Ⴠ Nominal voltage 300 Conditionally resistant to Oil Solvents Acids Lyes Ⴠ Test voltage 1500 V Ⴠ Breakdown voltage min. Weight app. weight kg km Outer Ø app. mm² Part no.cores x cross-sec. ASTM-B 174-95 class J-M, AWG 18-16 gem.50.182 and 50.Command Cable (LiYCY)Style 2464, 300 80°C, EMC-preferred type Properties Cable structure Technical data Ⴠ Tinned copper, fine wire conductors AWG 26-20 gem. mm AWG-No. mm² Part no. 3000 V Ⴠ Core insulation special PVC class respectively semirigid acc. Ⴠ Cores stranded layers with optimal lay-length non-screened analogue types: command cable (LiYY), confer page 403 Ⴠ Seperator-foil Ⴠ Drain wire Ⴠ Tinned copper wire braiding, approx