Poznámky redaktora
6
Ⴠ Low adhesion, extremely abrasion resistant,
resistant hydrolysis and microbial attack
Ⴠ Minimum bending radius
SENSORFLEX® two-approvals PVC
15x cable Ø
SENSORFLEX® two-approvals PUR
7,5x cable Ø
Special feature
Ⴠ Core insulation PVC
Ⴠ The cables with the highly flexible
stranded conductor cl.
SENSORFLEX® 2-APPROVALS
AWG-No.
Weight
app. These cables are used connector systems for sensors and actuators. 79907, 75642, 79850
Ⴠ The types with PVC/PUR sheath
material have PVC inner sheath,
with PUR sheath applied over it
by means coextrusion
Ⴠ Construction per SENSORFLEX®
two-approvals
Ⴠ Core insulation polypropylene
Note
Ⴠ AWG sizes are approximate equivalent
values.6, extra fine-wire,
BS 6360 cl.
weight
kg km
Outer Ø
app.5, IEC 60228 cl. Moving the
I/O points the system periphery enables significant reductions installation costs. While previously was necessary carry out time-consuming wiring switchgear cabinets and machines, now
field bus technology has made possible move the periphery interfaces from the switchgear cabinets the machines and systems.
Cable structure
Part no. The actual cross-section mm².
= The product conformed with the Low-Voltage Directive 2006/95/EC. combination with
injected circular connectors and installed actuator-sensor boxes, they constitute important connecting element between the periphery and the PLC
in production systems.SENSORFLEX® VERTEILERFLEX
two-approvalssensor actuator and distributor cables PVC, PUR, PVC/PUR
Properties
Cable structure
PVC cables
Technical data
PVC cables
Ⴠ Special PVC PUR sheath acc.5, fine-wire,
BS 6360 cl.
Application
For decentralised installation and control technology.6, IEC 60228 cl. The assembled cables offer attractive opportunities for reducing costs, not only the field automation technology, but also
in the entire manufacturing industry.cores x
cross-sec.
mm²
Sheath colour
24
18,0
7,2
4,4
X
BN, BU, BK
PUR
3 0,25
GY RAL 7001
78284
24
18,0
9,6
4,7
X
BN, BU, BK, WH
PUR
4 0,25
GY RAL 7001
79907
24
36,0
14,4
5,2
X
BN, BU, BK, WH, GY, PK
PVC
6 0,25
GY RAL 7001
78286
22
30,0
9,8
4,9
X
BN, BU, BK
PVC
3 0,34
GY RAL 7001
76345
22
43,0
13,1
5,2
X
BN, BU, BK, WH
PVC
4 0,34
GY RAL 7001
76347
22
54,0
16,4
5,9
X
BN, BU, BK, WH, GN-YE
PVC/PUR
5 0,34
GY RAL 7001
76348
22
54,0
16,4
5,9
X
BN, BU, BK, WH, GN-YE
PVC/PUR
5 0,34
GY RAL 7001
76349
22
54,0
16,4
5,9
X
BK with number, GN-YE
PVC/PUR
5 0,34
GY RAL 7001
78287
22
54,0
16,4
5,9
X
BN, BU, BK, WH, GN-YE
PUR
5 0,34
GY RAL 7001
79850
18
58,0
21,6
6,7
X
BK with number, GN-YE
PVC
3 0,75
GY RAL 7001
73571
18
58,0
21,6
5,9
X
BK with number, GN-YE
PUR
3 0,75
BK RAL 9005
75642
18
88,0
28,8
6,7
X
BN, BU, GN-YE
PVC
3 0,75
GY RAL 7001
76351
18
58,0
21,6
5,9
X
BK with number, GN-YE
PUR
3 0,75
GY RAL 7001
78288
Continuation Ⴇ
Cables according international Approvals Data Cables UL/CSA
411
N
. mm
High
flex **
Fine
wire
Core colours
Sheath
material
No.6, are
suitable for drag chain applications
Ⴠ Core identification see table below
Ⴠ Outer sheath PUR
Part no.
kg km
Cop. to
- UL-Style 2464 for PVC
- UL-Style 20233 for PUR
Ⴠ Extensively oil resistant;
Chemical Resistance (see table
Technical Informations)
Ⴠ Bare copper-conductor, to
DIN VDE 0295 cl.5
Ⴠ Temperature range
flexing -5°C +80°C
fixed installation -30°C +80°C
Ⴠ Ⴠ
Core insulation PVC PVC self-extinguishing and flame retardant
acc. DIN VDE 0482-332-1-2,
DIN 60332-1-2, IEC 60332-1 (equivalent
DIN VDE 0472 part 804 test method B)
Ⴠ Core identification see table below
Ⴠ Nominal voltage U0/U 300/500 Outer sheath special PVC
Ⴠ Test voltage
up 0,25 mm² 1200 V
from 0,34 mm² 2000 V
PUR cables
PUR cables
Ⴠ Bare copper-conductor, to
DIN VDE 0295 cl