HELUKABEL: Katalog kabelů a vodičů 2018 (EN)

| Kategorie: Katalog  |

Vydal: Helukabel CZ s.r.o.

Strana 411 z 1153

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.

Jak získat tento dokument?






Poznámky redaktora
TRAYCONTROL® 300 TPtwisted pair, flexible, oil-resistant, NFPA Edition 2012 Properties Cable structure Technical data Ⴠ Tinned copper conductor, fine wire stranded, with AWG measures Ⴠ Ⴠ Flexible PVC data and control cable Self-extinguishing and flame retardant in acc. 2, NEC Art. Weight app. 725, 760 800, NFPA 2012 Ⴠ Separator Ⴠ Outer sheath special PVC Ⴠ CSA: CSA CMG FT4, AWM I/II A/B FT4 Ⴠ Sheath colour grey (RAL 7001) Ⴠ with length marking feet Note Advantages Ⴠ Highly-flexible, easy install Ⴠ Oil-resistant OIL RES II Available request Ⴠ PUR TPE outer sheath Ⴠ Sheath colour suit customer requirement Application HELUKABEL® TRAYCONTROL® 300 twisteded pair data and control cable. kg km Cop. Cross-sections with PLTC-ER and ITC-ER approval for open, unprotected installation cable trays the machine; their outstanding oil resistance (OIL RES II) makes them ideally suited connecting and joining cables and also for control, signal and measuring systems industrial plants. Applications: tool machines, control panels, measuring devices, production automation, cable ducts, renewable energies. weight kg km Outer Ø app. Cross- section mm² Part no.cores x AWG-no. = The product conformed with the Low-Voltage Directive 2006/95/EC. mm No. kg km Cop.cores x AWG-no. weight kg km Outer Ø app. mm No. CSA FT4 Ⴠ Temperature range -25°C +105°C The materials used manufacture are free of silicone, cadmium and substances that impair paint wetting Ⴠ Core insulation special PVC (AWG AWG with transparent nylon skin) Ⴠ Nominal voltage 300 V Ⴠ Test voltage 2000 V Tests Ⴠ Core identification (pair) acc. Cross- section mm² Part no.pairs x No. 501, 725, 760 800, AWM 2517 Ⴠ Cores stranded pairs with optimal lay-length Ⴠ Radiation resistance up 80x106 cJ/kg (up Mrad) Ⴠ Pairs stranded layers with optimal lay-length (AWG AWG 26): CM, AWM 2464, rated OIL RES II, NEC Art. Weight app.pairs x No. to international colour code Ⴠ Minimum bending radius flexing cable (AWG AWG 18): PLTC-ER, ITC-ER, Type CM, NFPA 2012, OIL RES II, Class Div. 20,0 3,0 3,6 1 26 0,154 62794 185,0 79,0 12,1 16 24 0,241 61951 209,0 89,0 13,5 18 24 0,241 61952 24,0 5,0 5,1 2 26 0,154 62795 30,0 8,0 5,3 3 26 0,154 62796 230,0 98,0 14,4 20 24 0,241 61953 248,0 109,0 15,3 22 24 0,241 61954 38,0 11,0 5,8 4 26 0,154 62797 44,0 14,0 6,2 5 26 0,154 62798 279,0 118,0 16,1 24 24 0,241 61955 292,0 124,0 16,7 25 24 0,241 61956 51,0 16,0 6,8 6 26 0,154 62799 57,0 19,0 6,9 7 26 0,154 62800 38,0 7,0 4,2 1 22 0,382 61957 64,0 22,0 7,3 8 26 0,154 61928 44,0 13,0 6,4 2 22 0,382 61958 76,0 27,0 7,4 10 26 0,154 61929 60,0 20,0 6,8 3 22 0,382 61959 93,0 33,0 9,1 12 26 0,154 61930 79,0 29,3 9,2 4 22 0,382 61960 103,0 38,0 9,8 14 26 0,154 61931 92,0 33,0 8,2 5 22 0,382 61961 109,0 41,0 10,6 15 26 0,154 61932 119,0 39,0 8,9 6 22 0,382 61962 112,0 43,0 10,7 16 26 0,154 61933 128,0 46,0 9,0 7 22 0,382 61963 119,0 49,0 11,1 18 26 0,154 61934 139,0 52,0 9,9 8 22 0,382 61964 130,0 54,0 11,9 20 26 0,154 61935 171,0 65,0 11,7 10 22 0,382 61965 150,0 59,0 12,4 22 26 0,154 61936 194,0 78,0 12,4 12 22 0,382 61966 169,0 65,0 13,1 24 26 0,154 61937 222,0 92,0 13,0 14 22 0,382 61967 178,0 67,0 13,4 25 26 0,154 61938 231,0 98,0 13,2 15 22 0,382 61968 32,0 5,0 3,9 1 24 0,241 61939 240,0 105,0 13,3 16 22 0,382 61969 264,0 118,0 14,2 18 22 0,382 61970 36,0 10,0 5,9 2 24 0,241 61940 48,0 15,0 6,2 3 24 0,241 61941 291,0 131,0 15,1 20 22 0,382 61971 300,0 144,0 15,8 22 22 0,382 61972 56,0 20,0 6,5 4 24 0,241 61942 71,0 25,0 7,2 5 24 0,241 61943 359,0 157,0 17,0 24 22 0,382 61973 381,0 163,0 17,5 25 22 0,382 61974 80,0 29,0 8,1 6 24 0,241 61944 89,0 34,0 8,2 7 24 0,241 61945 60,0 11,0 5,2 1 20 0,616 61975 98,0 39,0 8,9 8 24 0,241 61946 80,0 22,0 8,8 2 20 0,616 61976 111,0 49,0 10,5 10 24 0,241 61947 94,0 32,0 9,3 3 20 0,616 61977 135,0 59,0 11,0 12 26 0,241 61948 104,0 43,0 10,2 4 20 0,616 61978 160,0 69,0 11,6 14 24 0,241 61949 130,0 54,0 11,3 5 20 0,616 61979 171,0 74,0 12,0 15 24 0,241 61950 151,0 65,0 12,5 6 20 0,616 61980 Continuation Ⴇ Cables according international Approvals Data Cables UL/CSA 409 N . The flexible cable structure facilitates installation inside and outside machines and switch cabinets