HELUKABEL: Katalog kabelů a vodičů 2018 (EN)

| Kategorie: Katalog  |

Vydal: Helukabel CZ s.r.o.

Strana 343 z 1153

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.

Jak získat tento dokument?






Poznámky redaktora
.Halogen-Free RG-Coaxial Cables 214 U 213 U 71 B/U 62 A/U 59 B/U 58 C/U 11 A/U Type RG. velocity propagation % Insulation resistance 10 5 10 5 10 5 10 5 10 5 10 5 10 5 MOhm kmmin.. Loop resistance 10 10 136 155 171 53 23 max. bending radius approx. (RM01) Note Ⴠ The materials used manufacture are cadmium-free and contain silicone and free from substances harmful the wetting properties lacquers. mm 203 155 64 54 57 38 144 Weight approx. Ⴠ RG/U: R=Radio, G=Guide, U=Utility Ⴠ FRNC Flame Retardant Non-Corrosive Application Coaxial cables are used high frequency transmission, especially for transmitters and receivers, computers, radio and transmissions where no flame propagation under behaviour fire permitted./U 40196 40195 40194 40193 40192 40191 40190 Part no. The varied mechanical, thermal and electronic properties Coaxial cables mean that they can be used into the GHz levels, per cable type. Cable structure 7 0,8 7 0,8 Copper, bare 1 0,6 Steel/copper, bare 1 0,6 Steel/copper, bare 1 0,6 Steel/copper, bare 19 0,2 Tinned copper 7 0,4 Tinned copper Inner conductor diameter mm Silvered copper 7,24 PE 7,24 PE 3,7 PE, hollow 3,7 PE, hollow 3,7 PE 2,95 PE 7,3 PE Insulation mm 2 braids Braid 2 braids Braid Braid Braid Braid Outer conductor 2x silvered copper Copper, bare Copper, bare Copper, bare Copper, bare Tinned copper Copper, bare - - Tinned copper - - - - HM2 HM2 HM2 HM2 HM2 HM2 HM2 Outer sheath 50 50 30 30 30 25 50 Min. (Ohm/km) 5 5 1 1 2 2 5 Nominal peak voltagekVs Dielectric strength 10 10 3 3 7 5 10 50 HzkVeff. 341 Coaxial Cables M . km Electrical characteristics 50 2 50 2 93 3 93 5 75 3 50 2 75 3 Impedance (Ohm) Frequency range 11 3 3 3 3 3 3 f (max. Ⴠ H-outer sheath halogen-free material (HM2) Ⴠ RG-Coaxial types are accordance with US-Military specifications MIL-C-17. mm -35 +80 -35 +80 -50 +70 -35 +80 -35 +80 -35 +80 -35 +80 Temperature range °C 120,0 85,0 48,0 28,0 28,0 29,0 58,0 Copper weight kg/km 10,8 10,3 6,9 6,4 6,4 5,4 10,3 Outer approx. Dimensions and specifications may changed without prior notice.) GHz 0,7 0,7 0,8 0,8 0,7 0,7 0,7 Propagation velocity v/c Attenuation 20°C (db/100m) 1,2 1,2 2 2 2 2,9 1,3 3 MHz 2,3 2,3 3,7 3,7 3,8 5,3 2,4 10 MHz 7,5 7,5 12,5 12 12,2 17 7,8 100 MHz 10,9 10,9 17,3 17,3 17,6 24,4 11,3 200 MHz 17,2 17,2 24,7 24,7 27,2 39,2 18,7 500 MHz 22,6 22,6 34,6 34,6 35,2 47,8 23,4 800 MHz 101 101 42,5 42,5 68 0 68 CapacitancepF/m 101 101 43 43 67 67 67 Rel