Poznámky redaktora
20
10,0
4,8
1,9 2,4
0,5
541xx 16
24,0
14,4
2,8 3,5
1,5
544xx
18
15,0
7,2
2,1 2,6
0,75
542xx 14
35,0
24,0
3,4 4,3
2,5
545xx
17
16,0
9,6
2,2 2,8
1
543xx 12
53,0
38,0
4,0 5,0
4
546xx
H05G-K (fine wire) H07G-K (fine wire)
AWG-No.
= The product conformed with the Low-Voltage Directive 2006/95/EC.
mm
Cross-
section
mm²
Part no.
AWG-No.
Weight
approx.
mm
Cross-
section
mm²
Part no.
Application
For inside wiring switch boards and distributors well operating parts such lights, for the connection electric heaters with a
nominal voltage 1000 alternating voltage 750 direct voltage against ground.
kg km
Cop.
Weight
approx. (RK01)
302
Single Conductors
.
weight
kg km
Outer Ø
min.
kg km
Cop.H05G-U H07G-U -K
Properties
Cable structure
Technical data
Ⴠ Tinned Cu-conductor, to
DIN VDE 0295, IEC 60228, 6360
class single-wire
class multi-wire
class fine-wire
Ⴠ Ⴠ
Heat-resistant (+110°C)
rubber-insulated cable to
DIN VDE 0285-525-2-42/
DIN 50525-2-42
Single core colours green and yellow can
only applied where the safety
regulations are allowed
Ⴠ The identification for the lighting chain
cable green permitted
Ⴠ Max. max. max. max.
weight
kg km
Outer Ø
min. max.
Weight
approx.
mm
Cross-
section
mm²
Part no. permissible operating
temperature
at conductor +110°C Note
Ⴠ Separating foil over conductor permitted
Ⴠ Core insulation rubber
compound type EI3 (EVA) to
DIN VDE 0207-363-1 DIN 50363-1
Ⴠ Lowest ambient temperatures
flexing -25°C
fixed installation -40°C
Ⴠ Please complete the part number for
these cores adding the suffix for
the colour required per the list:
00 green
01 black
02 blue
03 brown
04 grey
05 orange
06 pink
07 turquoise
08 white
09 violet
10 yellow
11 green-yellow
Ⴠ Nominal voltage
H05G U0/U 300/500 V
H07G U0/U 450/750 V
Ⴠ Test voltage
H05G 2000 V
H05G 2500 V
Ⴠ Minimum bending radius
fixed installation
core mm: core Ø
core 8-12 mm: core Ø
core mm: core Ø
Ⴠ bare conductor request
Ⴠ AWG sizes are approximate equivalent
values. The actual cross-section mm².
mm
Cross-
section
mm²
Part no.
H07G-U (single wire)
H05G-U (single wire)
AWG-No.
16
24,0
14,4
3,0 3,7
1,5
553xx
20
13,0
4,8
2,1 2,6
0,5
550xx
14
42,0
24,0
3,6 4,5
2,5
554xx
18
16,0
7,2
2,2 2,8
0,75
551xx
12
61,0
38,0
4,3 5,4
4
555xx
17
22,0
9,6
2,4 2,9
1
552xx
10
78,0
58,0
4,8 6,0
6
556xx
8
130,0
96,0
6,0 7,6
10
557xx
6
212,0
154,0
7,1 8,9
16
558xx
4
323,0
240,0
8,8 11,0
25
559xx
2
422,0
336,0
10,1 12,6
35
560xx
1
527,0
480,0
11,9 14,9
50
561xx
2/0
726,0
672,0
13,6 17,0
70
562xx
3/0
937,0
912,0
15,5 19,3
95
563xx
4/0
1192,0
1152,0
17,1 21,4
120
564xx
H07G-R (multi wire)
AWG-No.
kg km
Cop.
Weight
approx. These single cores are all allowed for laying tubes,
on and under plaster. AWG-No.
kg km
Cop.
mm
Cross-
section
mm²
Part no.
kg km
Cop. max.
Weight
approx.
weight
kg km
Outer Ø
min.
weight
kg km
Outer Ø
min.
10
72,0
58,0
4,7 5,9
6
547xx
8
123,0
96,0
6,0 7,4
10
548xx
6
184,0
154,0
6,8 8,5
16
549xx
Dimensions and specifications may changed without prior notice.
weight
kg km
Outer Ø
min