20 10,0 4,8 1,9 2,4 0,5 541xx 16 24,0 14,4 2,8 3,5 1,5 544xx 18 15,0 7,2 2,1 2,6 0,75 542xx 14 35,0 24,0 3,4 4,3 2,5 545xx 17 16,0 9,6 2,2 2,8 1 543xx 12 53,0 38,0 4,0 5,0 4 546xx H05G-K (fine wire) H07G-K (fine wire) AWG-No. = The product conformed with the Low-Voltage Directive 2006/95/EC. mm Cross- section mm² Part no. AWG-No. Weight approx. mm Cross- section mm² Part no. Application For inside wiring switch boards and distributors well operating parts such lights, for the connection electric heaters with a nominal voltage 1000 alternating voltage 750 direct voltage against ground. kg km Cop. Weight approx. (RK01) 302 Single Conductors . weight kg km Outer Ø min. kg km Cop.H05G-U H07G-U -K Properties Cable structure Technical data Ⴠ Tinned Cu-conductor, to DIN VDE 0295, IEC 60228, 6360 class single-wire class multi-wire class fine-wire Ⴠ Ⴠ Heat-resistant (+110°C) rubber-insulated cable to DIN VDE 0285-525-2-42/ DIN 50525-2-42 Single core colours green and yellow can only applied where the safety regulations are allowed Ⴠ The identification for the lighting chain cable green permitted Ⴠ Max. max. max. max. weight kg km Outer Ø min. max. Weight approx. mm Cross- section mm² Part no. permissible operating temperature at conductor +110°C Note Ⴠ Separating foil over conductor permitted Ⴠ Core insulation rubber compound type EI3 (EVA) to DIN VDE 0207-363-1 DIN 50363-1 Ⴠ Lowest ambient temperatures flexing -25°C fixed installation -40°C Ⴠ Please complete the part number for these cores adding the suffix for the colour required per the list: 00 green 01 black 02 blue 03 brown 04 grey 05 orange 06 pink 07 turquoise 08 white 09 violet 10 yellow 11 green-yellow Ⴠ Nominal voltage H05G U0/U 300/500 V H07G U0/U 450/750 V Ⴠ Test voltage H05G 2000 V H05G 2500 V Ⴠ Minimum bending radius fixed installation core mm: core Ø core 8-12 mm: core Ø core mm: core Ø Ⴠ bare conductor request Ⴠ AWG sizes are approximate equivalent values. The actual cross-section mm². mm Cross- section mm² Part no. H07G-U (single wire) H05G-U (single wire) AWG-No. 16 24,0 14,4 3,0 3,7 1,5 553xx 20 13,0 4,8 2,1 2,6 0,5 550xx 14 42,0 24,0 3,6 4,5 2,5 554xx 18 16,0 7,2 2,2 2,8 0,75 551xx 12 61,0 38,0 4,3 5,4 4 555xx 17 22,0 9,6 2,4 2,9 1 552xx 10 78,0 58,0 4,8 6,0 6 556xx 8 130,0 96,0 6,0 7,6 10 557xx 6 212,0 154,0 7,1 8,9 16 558xx 4 323,0 240,0 8,8 11,0 25 559xx 2 422,0 336,0 10,1 12,6 35 560xx 1 527,0 480,0 11,9 14,9 50 561xx 2/0 726,0 672,0 13,6 17,0 70 562xx 3/0 937,0 912,0 15,5 19,3 95 563xx 4/0 1192,0 1152,0 17,1 21,4 120 564xx H07G-R (multi wire) AWG-No. kg km Cop. Weight approx. These single cores are all allowed for laying tubes, on and under plaster. AWG-No. kg km Cop. mm Cross- section mm² Part no. kg km Cop. max. Weight approx. weight kg km Outer Ø min. weight kg km Outer Ø min. 10 72,0 58,0 4,7 5,9 6 547xx 8 123,0 96,0 6,0 7,4 10 548xx 6 184,0 154,0 6,8 8,5 16 549xx Dimensions and specifications may changed without prior notice. weight kg km Outer Ø min