5, IEC 60228 cl. MOhm km
Note
Ⴠ Minimum bending radius
fixed insatallation core The following colours are recommended:
black, white, blue, grey, brown, red,
orange, turquoise, violet and pink.
weight
kg km
Outer Ø
min.
9,6
2,4 2,8
1
Spool (with various capacity)
Packing
H05V-K spool
26389
26605
26604
26603
26602
26601
26600
26599
26598
26597
26596
26595
26594
26593
26592
26591
26590
Part no.
= The product conformed with the Low-Voltage Directive 2006/95/EC.5, fine-wire,
BS 6360 cl.
7,2
2,2 2,7
0,75
26388
29128
29127
29126
29125
29124
29123
29122
29121
29120
29119
29118
29117
29116
29115
29114
29113
Part no.
4,8
2,1 2,5
0,5
26390
26621
26620
26619
26618
26617
26616
26615
26614
26613
26612
26611
26610
26609
26608
26607
26606
Part no. RAL
Coil cardboard (100m)
Packing
H05V-K coil
26386
29096
29095
29094
29093
29092
29091
29090
29089
29088
29087
29086
29085
29084
29083
29082
29081
Part no.
mm²
5002
-
-
2003
5010
-
6018
3015
1021
4005
7001
9003
3000
8003
5015
-
9005
approx.
4,8
2,1 2,5
0,5
26387
29112
29111
29110
29109
29108
29107
29106
29105
29104
29103
29102
29101
29100
29099
29098
29097
Part no. Green is
permitted for the identification of
luminous decorative chains. All
2-coloured combinations the
abovesingle colours are allowed
Ⴠ Radiation resistance
up 80x106 cJ/kg (up Mrad)
Application
These single cores are determined for the installation the inside apparatus well for the protective laying the lightings, dry rooms, in
production facilities, switch and distributor boards, tubes, under and surface mounting plasters.
H05V-K
U-BU
2-col.5
Ⴠ Ⴠ
PVC single cores to
DIN VDE 0285-525-2-31 /
DIN 50525-2-31 and IEC 60227-3
The materials used manufacture are
cadmium-free and contain silicone
and free from substances harmful to
the wetting properties lacquers
Ⴠ Ⴠ
Temperature range
flexing -5°C +70°C
fixed installation -30°C +80°C
Core insulation PVC
compound type TI1 to
DIN VDE 0207-363-3 DIN 50363-3
and IEC 60227-3
Tests
Ⴠ PVC self-extinguishing and flame retardant
acc.
o.
mm
Cross-
sec. max.
Exceptions are the colours green and
yellow; these are only permitted the
safety regulations allows.H05V-K PVC-Single Cores, fine wire stranded
Properties
Cable structure
Technical data
Ⴠ Bare Cu-conductor, to
DIN VDE 0295 cl.
9,6
2,4 2,8
1
Continuation Ⴇ
289
Single Conductors
K
.
7,2
2,2 2,7
0,75
26391
26637
26636
26635
26634
26633
26632
26631
26630
26629
26628
26627
26626
26625
26624
26623
26622
Part no.col. DIN VDE 0482-332-1-2,
DIN 60332-1-2, IEC 60332-1 (equivalent
DIN VDE 0472 part 804 test method B)
Ⴠ Nominal voltage U0/U 300/500 V
Ⴠ Core identification see table below
Ⴠ Test voltage 2000 V
Ⴠ Insulation resistance
min.
OG
D-BU
TRANS
GN
PK
YE
VT
GY
WH
RD
BN
BU
GN-YE
BK
Cop